Example 1:
If, under pH-control, you enter CO2-supply as control type and pH 6.5 as control value, the
control process is
activated
as soon as the pH-value
exceeds
pH 6.5. It remains active until the value falls
again below pH 6.45 (Note: The switch hysteresis of pH 0.05 is designed to prevent the solenoid valve
clicking).
Example 2:
In the 'temperature control' mode enter 'heat' as the control type and 24°C as the value. If the
temperature in the tank falls below 24°C, the hating system is activated. When the temperature rises again to
over 24°C the heating switches off again.
25 Value(Night)?
Appears for
pH and temperature
. As in Point 23. Here, however, you enter the value that is to apply as
control value during the
night
.
26 Value?
Enter the
control value
here. It applies to day and night!
27 Upper alarm?
If the value that you have entered here is
exceeded
, an alarm is activated and the
control process
stopped
.
28 Lower alarm?
As in 25 except that the alarm is activated when the value
falls below
the entered value.
A hint regarding the alarm settings:
The function of the alarms is to warn the user about a possible
malfunction. Please leave sufficient leeway between the programmed control processes and the alarm points
as a living system, such as an aquarium, is governed by a wide variety of factors and is always subject to
natural fluctuations!
29 Which socket?
Here you can state the
number of the socket
to which
your controllable appliance (e.g. heater) is
connected. On the socket panel L1 are the sockets 1-4, on L2
à
5 –8. The switch socket from thePower
Station (L0) has the number ‘’0’’.
2A CntrlblSocket?
If the socket selected in [29] is one with variable-output (dimmable) then this menu will follow. Here the
output can be entered as a percentage, first for the switched on phase and then for the switched off phase.
You can check straightaway that the set values are the ones you really want by pressing the
del
key.
Example:
You want to run a controllable pump that operates at full power (100%) when switched on and still
produces a slight "base current" when switched off. To do this you set the desired percentage when entering
the "Off" value. You can use [del] to check immediately if the current is as you want it.
2C Value(Su, Day)?
(only in the "Professional" level)
Daytime temperature in summer.
2D Value(Su, Nite)?
(only in the " Professional " level)
Night-time temperature in summer
2E Value(Wi, Day)?
(only in the " Professional " level)
Daytime temperature in winter.
2F Value(Wi, Nite)?
(only in the " Professional " level)
Nite-time temperature in winter.
2G Alarm time?
For the water level control, as an alarm you can enter a time after which your control is automatically
switched off
for safety
.