iks aquastar midi
43
2K Control in the
If “aquarium” is selected, the control process functions as described in section 13.1. . If “pond” is selected,
the control process is carried out using a time lag.
8.3 Time functions
31
Time control type
Here you can select which type of time control process you want to programme. You can select between:
current simulation (current and high-/ low tide), day/night simulation, lunar phase, timer and interval
32 CuProcessNo.?
(only in the "Pro" level)
You can allocate a current function to each one of up to 16 independent pumps. Here you select the
appropriate process with the number you enter. The number in brackets states which socket the selected
process is connected to. “(--)” means that the process has not yet had a process allocated to it.
33 Current simulation
Select whether you want to deactivate the current simulation "(Off)" or whether you want to produce a
simulation of current or high-/ low tide. The
current simulation
activates
one pump
, the
high-/ low tide
simulation
activates
two pumps
alternately.
34 Waves
If you enter "Yes" your
controllable pump
will pulsate (simulate a wave).
35 Wave duration
Here you can enter how long the pulse duration should be for a wave.
36 Nocturnal fall
By entering "Yes" the current can be
reduced at nite
.
37 Fall of
At night
the output of the relevant socket (On- and Off value) is
reduced by this amount.
For example: a
night-time value of 60% is produced with "Fall of 20%" from a daytime value of 80%. A daytime 10%
becomes 0% at night. You can enter the duration of the night under
à
Time functions
à
Day/ night
simulation.
38 Tide duration
In the high-/ low tide simulation
two pumps
work in constant alternation. This is where you programme how
long each pump is on.
Example: 06:00:00 Pump 1 runs for 6 hours then Pump 2 for 6 hours, Pump 1 is off. Afterwards, Pump 1
restarts.
39 Random factor
Here you enter a
range of random operation.
The system then prolongs the interval by a random period
that is somewhere between 0 seconds and the random factor that you have entered.
3A SocketLoTide?
As in 29. Here you state the
socket
that is to be active during
low tide
.
3B SocketHiTide?
As in 29. Here you state the
socket
that is to be active during
high tide
.
3C Li ProcessNo.?
(only in the "Pro" mode)
You can programme eight different processes for
light simulation
too. This is where you enter the desired
process number. The number in the brackets states with which socket the selected process is connected to.
“(--)” means that the process has not yet had a socket allocated to it.