14
DiSEqC Configuration
The RNS-101 module settings are grouped into six sections or categories: DiSEqC,
Input, Output, SAP Channel, CAM User Menu and SNMP. Click on the
Settings
menu
on the left side of the general programme screen. A drop down list is displayed offering
five options:
DiSEqC, Input, Output
,
SAP/SDP Channel,
CAM User Menu
and
SNMP
.
Click on
DiSEqC
. The Configuración DiSEqC window will appear:
"Activate DiSEqC" : Check the box if you want to equip the streamer with DiSEqC
function, either because you have to feed/control an LNB or because a multiswitch
is installed in the headend. Otherwise leave the box unchecked.
"Number of inputs" : It refers to the number of SAT inputs of the multiswitch (if there
is no multiswitch, and the matter is to feed/control an LNB, choose "4"). When
choosing, a multiple pop-up box, with a number of rows equal to the number
chosen, appears on the field below (see Figure 2.2).
"Description of each input" : If there is no multiswitch and the streamer has to feed/
control an LNB, fill the polarity/band columns with the selections that appear in the
first four rows of Figure 2.2. If there is a multiswitch, you have to know what IF
signal (satellite, polarisation, band) is connected to each one of the inputs of that
one; with this information at hand, fill in all the rows of the box.
Figure 2.1 - DiSEqC Configuration window — DiSEqC deactivated
Figure 2.2 - DiSEqC Configuration window — Description of multiswitch inputs
Once all data is entered, click on
Send
to conclude the DiSEqC configuration.
DiSEqC