12
Basic installation and configuration
/IKUNET bus configuration
Name of slave modules
Continue without connecting the IKUNET bus.
Follow the steps below for each of the remaining modules of the headend (slave modules).
1)
Connect the selected module ( A ) to the PC
( B ) via its Ethernet connection and using an
RJ-45 cable ( C ).
2)
Enter the IP address http://10.254.254.254 in
the web browser. This takes you to the home
page of the connected module.
3)
In the home page of the selected module,
“Admin” appears by default in the
USer
field.
Enter the word “admin” in the
paSSword
field
and click on
aCCept
.
4)
Enter the name of the module in the
modUle
name (StC-2
) field.
CAUTIoN
The
thiS StC-100 iS the maSter modUle
checkbox must be left un-
marked for the slave modules
.
5)
Click on
Save.
6)
Click on
exit
in the main screen (top right corner).
General configuration of the headend
When the master module for the headend has been defined, access to the headend is via
the master module. To access the master module it is necessary to configure the IP access
of the PC and enter another IP address in the web browser.
1)
Connect the IKUNET bus for the headend with the Ethernet pigtails supplied together
with each module (see example in the figure in the
General description
section).
2)
In the PC, modify the IP address, following the same steps as in
Definition of the
master module
, but including the following parameters:
F
ip addreSS
: it should follow the root of the IP address for the master module of
the headend, but be out of its range. The address recommended by IKUSI for the
default configuration of the master module is 192.168.1.2.
F
SUbnet maSk
: 255.255.255.0
F
defaUlt gateway
: 192.168.1.1
3)
Click on the
aCCept
button.
4)
In the web browser, enter the IP address of the master module. The default address is
http://192.168.1.5. This takes you to the home page of the headend master module.
STC-100