LED
LIT
FLASHING
OFF
CAN_RUN
Operating status
Pre-operating status
CAN communication non
active
CAN_ERR
Communication OK
Communication error
CAN controller disconnected
If the problem is associated with the equipment, please send both the transmitter and the
receiver to the your Technical Assistance Service Agent, together with a description of the
problem and the status of the LED’s.
If the transmitter becomes so damaged that a spare has to be arranged, it can be quickly
substituted by following the instructions in ANNEX A.
Display error messages V 2.4:
Error message
Cause
"Tilt switch "
Inclinometer detected due to an incorrect position of the
transmitter
"Out of Range"
Transmitter out of range
"Wrong Crane "
Crane selector is in wrong position after a crane has been
selected previously
"Error EEP"
Error when trying to access the content of the EEPROM or the
internal memory. The content of the EEPROM cannot be copied
into the internal memory
"Error Wrong
EEP"
EEPROM data corrupted
"Error Copy
FLASH"
When duplicating EEPPROM modules a copy failure occured
during the new EEPROM updating process
"Error Open File"
Internal memory access failure
"Error File Write"
Error when writing EEPROM data into the flash memory or
timeout error occured when trying to access to the memory
"Error File Close"
Error when trying to close the internal memory access
"Error Open
Radio"
The radio cannot be opened
"Error Write
Radio"
Data cannot be written in the radio
"Error OP &
Masc"
When releasing the STOP pushbutton the signals and the masks
do not match indicating that some masked order is still activated.
"Error Bad data
EEP"
EEPROM data corrupted
"Error LAL not
open"
Error when trying to open the range limiter
"Error Read LAL
err"