TM70Bi V3.2 (11/02)
1121174 L0.pdf
26
IKUSI reserves the right to change this information without prior notice.
100D: LIFE TIME FACTOR
1014: COB-ID EMCY
1015: INHIBIT TIME EMERGENCY
1017: PRODUCER HEARTBEAT TIME
1018: IDENTITY OBJECT
1018.0: number of entries
1018.1: Vendor ID
1018.2: Product Code
1018.3: Revision Number
1018.4: Serial number
1800: TRANSMIT PDO COMMUNICATION PARAMETER
1800.0: number of entries
1800.1: COB-ID
1800.2: Transmission type
1800.3: Inhibit time
1800.4: Event timer
1A00: TRANSMIT PDO MAPPING PARAMETER
1A00.0: number of entries
1A00.1: PDO mapping entry
1A00.2: PDO mapping entry
1A00.3: PDO mapping entry
1A00.4: PDO mapping entry
6000: DIGITAL INPUT 8 BITS
6000.0: number of entries
6000.1: start and stop buttons (start1, start2, stop)
6000.2: buttons 1-4 (M1-M8)
6000.3: buttons 5-8 (M9-M16)
6000.4: buttons 9, 10 and auxiliary inputs (M17-M20, A1, A2)
9.4 - PDO
The system is provided with a 4 byte configured transmission PDO:
1
st
byte
2
nd
byte
3
rd
byte
4
th
byte
Object 6000.1 Object 6000.2 Object 6000.3 Object 6000.4
Start1
M1
M9
M17
Start2
M2
M10
M18
Stop
M3
M11
M19
0
M4
M12
M20
0
M5
M13
A1
0
M6
M14
A2
0
M7
M15
0
0
M8
M16
0
The PDO transmission is configured by default as “event driven”, this is, it is sent every time there is a
change on any input.