TM70 – ANALOGUE FEEDBACK / IN 0-10v OPTION / CALIBRATION
14.1 - INTRODUCTION
Systems with analogue feedback need to have the options Display and Analogue Feedback.
Systems with analogue feedback need at startup the calibration of the analogue input by the
distributor or the user. The following steps need to be done:
14.2 - CALIBRATION OF THE ANALOGUE FEEDBACK WITH LCD DISPLAY
Transmitters with display option, allow the operator the calibration of the analogue input through the
edition of a three digit value plus a comma and a measurement unit up to three characters.
The modified feedback calibration data will not be updated in the receiver EEPROM. In
order to do it, please copy the new information located in the transmitter EEPROM into
the receiver one.
At the remote control start up the Calibration must be done as follows:
1.
Insert a fully charged battery and turn ON the
contact key.
2.
Push and Pull the STOP pushbutton. An
orange blink will be seen on the LED followed
by green pulses.
3.
Place a known load on the crane in order to
introduce the First value in Calibration mode.
4.
Switch off the remote control and start the
system entering in CALIBRATION mode. In
order to do so, it is necessary to do the
following:
5.
Press push button number 4 up to second
speed
and
press
START.
Keep
both
pushbuttons pushed for a couple of seconds
until it appears on the display CONFIG mode.
6.
Press the push button number 4 to go inside the
MENU.
7.
To move through the menu, use pushbuttons 1 & 2 until CALIBRATION menu is reached.
8.
Press pushbutton 4.