TM70Bi V3.2 (11/02)
1121174 L0.pdf
62
IKUSI reserves the right to change this information without prior notice.
RELAY OUTPUTS
The following connections are available for each relay: normally open (NO), normally closed (NC) and common,
in the RL1 connector as shown in the following table.
Disposition of 4 manoeuvre relays of 250V/8A.
Pin
Function
1
K1 contact: normally closed
2
K1 common contact
3
K1 contact: normally opened
4
K2 contact: normally closed
5
K2 common contact
6
K2 contact: normally opened
7
K3 contact: normally closed
8
K3 common contact
9
K3 contact: normally opened
10
K4 contact: normally closed
11
K4 common contact
12
K3 contact: normally opened
Cod. 1141684: TM70 1M abatable base
Cod. 1184005: UNEX 2221-0 clip
Cod. 1095040: CAN RC70 1 expansion cable
Cod. 1131030: M3x6 C/R DIN84 screw
Cod. 2303908: A1P4RCAN electronic board
RL3
RL4
RL2
RL1
RL3
RL4
1
5
+VI
GN
1
5
+V
GN