background image

ILFORD

START and FINISH WORK

A simple sequence of actions prepares the
processor for its next operation. Press CLEAR, then
press 1 START WORK or 7 FINISH WORK, follow
the instructions. Wet the top rollers as shown using
the washing bottle. Take care to keep other areas
on the processor dry. The processor counts the total
number of films processed each day, press 4 FILM
COUNTER. If required this can be cleared at the
start or end of each day. 5 FILM POSITION displays
the location of films in the processor.

SETTING AND CHECKING
REPLENISHMENT RATES

Press CLEAR, then press 3 REP SET and follow the
instructions to set the rates, use the numbers on the
keypad to input data, then press CLEAR. Set the
rinse solution at 23 seconds max. To check the
actual rates - withdraw the replenishment pipe and
place in a measuring cylinder as shown. Press
CLEAR, then press 8 MANUAL REP. CONFIRM will
power the pump through one complete cycle. Power
the pump through 5 cycles. Take an average
reading of the total volume to find the actual rate,
adjust the rate if required and check again.

Replenishment pump flow rates and
operating times

Rep volume

Approximate rep time (seconds)

(ml/36 exp)

Fixer

Developer
and rinse solution

10

2.4

3.3

20

4.8

6.6

30

7.2

9.9

40

9.6

13.2

50

12.0

16.5

60

14.4

20.8

70

16.8

22.0

80

19.2

-

90

21.6

-

100

23.0

-

DEVELOPMENT TIMES

Six switches are pre-set to give development times shown
on the label. The switches can be re-set by adjusting a
control screw under the label. Press CLEAR, select DRIVE
on. Press the switch to be re-set, the display shows actual
temperature and time. Use a screwdriver, turn screw
clockwise to increase time, counter clockwise to reduce
time. Wait 10 seconds for the display to show actual time.
The development time can also be set with the selection
knob. Press CLEAR, select DRIVE on. Press M, turn knob
clock-wise to reduce time or counter clockwise to increase
time. Wait 10 seconds for display to show actual time.

IL806

Summary of Contents for ILFOLAB FP40

Page 1: ...une 1998 ILFORD Imaging UK Limited Mobberley Cheshire AIR PUMP ADJUSTMENTS The air pump controls air flow through the water in tank WS1 Remove rack 3 to see the amount of agitation With DRIVE on rotate the air pump adjusting knob clockwise to decrease the flow of air counter clockwise to increase the flow EMERGENCY PROCEDURES If the drive stops with a film in the processor fit the handle and turn ...

Page 2: ...ILFOLAB FP40 processor CONTROL PANEL Forward through sequence Back through sequence ENTER Record the new input data CONFIRM Verify the input data to memory CLEAR Clears the display shows the present state of the processor Press CLEAR at the start and end of each programming sequence POWER Switches the processor systems on DRIVE Switches on drive motor air pump and dryer TIMER Select for automatic ...

Page 3: ...M will power the pump through one complete cycle Power the pump through 5 cycles Take an average reading of the total volume to find the actual rate adjust the rate if required and check again Replenishment pump flow rates and operating times Rep volume Approximate rep time seconds ml 36 exp Fixer Developer and rinse solution 10 2 4 3 3 20 4 8 6 6 30 7 2 9 9 40 9 6 13 2 50 12 0 16 5 60 14 4 20 8 7...

Page 4: ... 6 TIMER SET and follow the instructions To set the days you want the timer to operate press 0 for off 1 for on DRAINING Remove lower panel withdraw bottle Remove top cap assembly Remove drain cap and fit nozzle pour out the effluent Refit caps replace bottle and refit panel Each working tank can be drained by opening the appropriate drain valve Place a bottle under the drain pipe Dev or Fix when ...

Reviews: