COFFEE BAR MANUAL
68
ILLY COLD BREW ARIA
Troubleshooting
1
IF THE LIGHT IS ON
Check for obstructions in the black Aria tap spout. Remove and clean as necessary. Be careful
not to lose the internal o-ring and plastic flow straightener inside the spout.
2
IF THE LIGHT IS BLINKING
1.
The pump shut off circuit has been activated. If the pump runs for 60 seconds
without liquid or pressure the safety system will activate. Turn pump switch
“OFF”
and
“ON”
to reactivate.
2. Check if there is coffee in the container. Refill if necessary.
3. Check for proper connection of intake black ball lock on the dispense line to the
“OUT”
stem of the keg. When finished, turn the pump
“OFF”
and
“ON”
again to reset.
3
IF THE LIGHT IS OFF
1.
Toggle the power switch to the
“OFF”
and
“ON”
position.
2. If the pump power light does not come on, check that both the unit power cords are
plugged in and that the pump power cable is plugged into the top of the pump.
3. If the unit still does not function, contact your illy representative:
(800)USA-ILLY (872-4559)
IF NO COFFEE DISPENSES FROM THE TAP
1. Close the tap
2. Open the unit door
3. Check the unit pump power light