background image

COFFEE BAR MANUAL

  68

ILLY COLD BREW ARIA 

Troubleshooting

1

IF THE LIGHT IS ON

Check for obstructions in the black Aria tap spout. Remove and clean as necessary. Be careful 
not to lose the internal o-ring and plastic flow straightener inside the spout.

2

IF THE LIGHT IS BLINKING

1. 

 

The pump shut off circuit has been activated. If the pump runs for 60 seconds
without liquid or pressure the safety system will activate. Turn pump switch 

“OFF”

and 

“ON”

 to reactivate.

 

2.  Check if there is coffee in the container. Refill if necessary. 

3.  Check for proper connection of intake black ball lock on the dispense line to the

“OUT”

 stem of the keg. When finished, turn the pump 

“OFF”

 and 

“ON”

 again to reset.

3

IF THE LIGHT IS OFF

1. 

 

Toggle the power switch to the 

“OFF”

 and 

“ON”

 position.

2.  If the pump power light does not come on, check that both the unit power cords are  

plugged in and that the pump power cable is plugged into the top of the pump. 

3.  If the unit still does not function, contact your illy representative:  

(800)USA-ILLY (872-4559)

IF NO COFFEE DISPENSES FROM THE TAP

1. Close the tap

2. Open the unit door

3. Check the unit pump power light

Summary of Contents for COLD BREW ARIA

Page 1: ...0 F 3 Inspect the dispense lines for black buildup or spots A If you detect black residue DO NOT USE THE UNIT The lines must be replaced Call illy Caffe Technical service to schedule a service call B...

Page 2: ...ld Cleaner See Chart 2 Place the basket insert into the solution or Toddy Nylon filter 3 Run 1 liter of water through the tap and Let sit for 15 minutes 4 After 15 minutes empty the remaining solution...

Page 3: ...e dispense line to the OUT stem of the keg and place the keg back into the unit 6 Place a container under the tap on the door To purge air from the system open the tap and turn ON the pump When the co...

Page 4: ...box 7 Place the bag in box stand inside unit with the taller open side on the right Turn bag in box upside down with the black ball lock connector on the dispense line in the downward position towards...

Page 5: ...e into the cardboard opening On the top of the box always record the date connected and expiration date Maximum 5 days after opening Connect the dispense line black ball connector to nozzle on the box...

Page 6: ...iner and let it soak for 15 minutes 5 6 CLEANING Urnex Clearly Cold Solution SANITIZING Urnex Complete Caf Solution Item US3560 Remove and rinse the keg and the grey air intake valve Re ll keg with 2...

Page 7: ...elease any residual pressure from the unit 4 Disconnect the black dispense line out from the keg or the BIB Bag in Box 5 Attach the black connector to the stem on the cleaning bottle and ensure it is...

Page 8: ...le Once attached pull up to ensure it is secured close the door of the unit with the bottle outside of the door and turn on Place a container under the tap spout Run the solution through the system fo...

Page 9: ...2 Check if there is coffee in the container Re ll if necessary 3 Check for proper connection of intake black ball lock on the dispense line to the OUT stem of the keg When nished turn the pump OFF and...

Reviews: