background image

SHENZHEN

SHENZHEN

ILOCKEY

ILOCKEY

TECHNOLOGY

TECHNOLOGY

CO.,LTD

CO.,LTD

Add: 6F Shuipan building, No 3193Binghe Avenue , Futian District, Shenzhen City. China 518033

TEL: +86-755-28689800

FAX: +86-755-28689801

Email: info@ilockey.com

Http://www.ilockey.com

2

General Information:

Exit setting mode: Enter * to exit the setting procedure, or wait for 10 seconds

Low battery warning: When the voltage drops below 5.2V after entering a valid code,
the lock beeps for three times.

Unlocking indicator: Music sounds and motor rotate.

Locking indicator: Red Light flashing one time, and music sounds and motor rotate.

Retrieve Factory Default:

a. Disconnect 1pcs battery

b. Press and hold the reset button

c. While holding the reset button, reconnect the battery
d. Until the lock beeps, release the reset button.
e. Press digit ‘1’ to retrieve factory default or other digit to abort reset procedure.
f. The lock must be set up again after the reset is complete.
Warning: After retrieve, all existing user codes and current programming code will

be erased. Default Programming Code will be restored , but

the enrolling of

lock with gateway will not be erased.

The reset button is located below the

battery holder. (See Picture)

Types to operate the lock:

User code unlock: 6 digits user code

Emergency unlock: 8 digits programming code + 9 (for emergency)

Wireless :Mobile or PC or PAD

Manual key: Turn the override key 90 degree clockwise, then turn the handle

Summary of Contents for IZ9015ZW-S

Page 1: ...OLOGY TECHNOLOGY CO LTD CO LTD Add 6F Shuipan building No 3193Binghe Avenue Futian District Shenzhen City China 518033 TEL 86 755 28689800 FAX 86 755 28689801 Email info ilockey com Http www ilockey c...

Page 2: ...ry Default a Disconnect 1pcs battery b Press and hold the reset button c While holding the reset button reconnect the battery d Until the lock beeps release the reset button e Press digit 1 to retriev...

Page 3: ...ns Z Wave Every unlocking need be through Z wave Controller Index No 2 digits For each user code It is associate with a unique number we call it index No The Index No is auto generated by lock and sta...

Page 4: ...e disable vocation mode Function Code 5 programming code 5 enable vocation mode Please be noted that the lock will not accept any user code but programming code only in vocation mode programming code...

Page 5: ...default the inclusion status of Z Wave is still effective Z wave Generic Information Generic Device Class GENERIC_TYPE_ENTRY_CONTROL Specific Device Class SPECIFIC_TYPE_ADVANCED_DOOR_LOCK FLIRS settin...

Page 6: ...E_PARAMETERS USER_CODE Z Wave Command Class Specific COMMAND_CLASS_APPLICATION_STATUS Device responses Application Rejected Request Command to source node while received invalid Set command COMMAND_CL...

Page 7: ...Lock Configuration Command Auto relock timeout fix in eight 8 seconds Device treats constant Unsecure setting of Door Lock Operation as Unsecure with timeout while device auto relock mode is enable C...

Reviews: