background image

INSTALLATION INSTRUCTIONS   

LED DUSK-TO-DAWN 

November 5, 2014 

 
 

ILP 

 Industrial Lighting Products, LLC 

519 Codisco Way, Sanford, FL 32771 

Phone: (407) 478 3759 Fax: (407) 478 3760 

www.ilp-inc.com 

 

 
 

2.  Arm mount luminaire to wall or vertical surface with supplied pipe arm: 

               

Step 1 

 

 
 
 
 
 

 
 
 
 
 

Assemble tube sections and secure with locknut 

(note: one section may be used to aim luminaire 

at high angle for longer forward light throw)

 

Step 2 

 

 
 
 
 
 

 
 
 
 
 

Feed supply wires through the arm assembly and 

connect to the power leads from the fixture. Slide 

the fixture over the arm and clamp securely. Ensure 

the fixture does not rotate on the arm before 

continuing.

 

Step 3 

 
 
 
 
 
 
 
 
 
 
 

Attach the mounting clamp to the arm and 

secure with the provided hardware. Ensure the 

clamp does not rotate on the arm before 

continuing.

 

Step 4 

 
 
 
 
 
 
 
 
 
 

 

Attach luminaire and arm assembly to wall or 

vertical surface securely with four screws. 

Apply 

silicone sealant around wire/wall opening

R

estore power to circuit and test to confirm 

proper operation.

 

 

 

Summary of Contents for D2D-50WLED-UNIV-00K Series

Page 1: ... Note Replace XX with 40 or 50 based on CCT of LED Model number parameter list CAUTION This product is supplied with a photocell Ensure replacement photocell is rated for the universal input voltage range of 100V 277V AC APPLICATION ITEMS Dimensions mm inches Model Input Voltage Power Factor Input Power Input Current 120VAC Weight D2D 50WLED 100 277VAC 0 95 50W 0 44A 8 5 lb 7 17 13 46 18 58 22 44 ...

Page 2: ... 104 F 40 C Suitable for wet Locations Note Save these instructions for future reference 1 Installation Use electrical wire rated for at least 194 F 90 C for supply connections Warning To avoid the risk of fire explosion or electric shock this product should be installed inspected and maintained by a qualified electrician in accordance with all applicable electrical codes Warning To avoid electric...

Page 3: ...r vertical surface Step 1 Turn power off Bore three holes per dimensions below around supply wires Step 2 Install the two lower screws bolts use wall anchors or self anchor bolts Step 3 Position luminaire on lower bolts install top bolt and tighten all three bolts Apply silicone sealant around supply wire and wall opening Step 4 Remove cover feed supply wires through clamp connect wires to luminai...

Page 4: ...forward light throw Step 2 Feed supply wires through the arm assembly and connect to the power leads from the fixture Slide the fixture over the arm and clamp securely Ensure the fixture does not rotate on the arm before continuing Step 3 Attach the mounting clamp to the arm and secure with the provided hardware Ensure the clamp does not rotate on the arm before continuing Step 4 Attach luminaire ...