background image

 USER MANUAL

 

 

© iLumi Solutions, Inc.                            

www.ilumisolutions.com

                            Confidential                            

Page 

1

 | 

21

              

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ilumi MeshTek® 0-10V Smart Lighting Controller 

(SLC)

 

 

Horticultural Lighting Control

 

 

User Manual 

Revision 1.8 

 

 

 

 

Summary of Contents for MeshTek 0-10V SLC

Page 1: ...USER MANUAL iLumi Solutions Inc www ilumisolutions com Confidential Page 1 21 ilumi MeshTek 0 10V Smart Lighting Controller SLC Horticultural Lighting Control User Manual Revision 1 8...

Page 2: ...SPECIFICATIONS 7 2 8 ABSOLUTE MAXIMUM RATINGS 7 CHAPTER 3 HARDWARE 8 3 1 CONNECTOR PINOUT 8 CHAPTER 4 GETTING STARTED 9 4 1 CONNECTING THE MESHTEK 1 CHANNEL 0 10V SLC TO LED DRIVER 9 CHAPTER 5 USING...

Page 3: ...on please contact the Marketing Communications Department via Email at info ilumisolutions com We welcome your feedback Errata An errata sheet describing minor operational differences from the data sh...

Page 4: ...tooth Low Energy BLE protocol Multiple lighting fixtures can be controlled individually or together as a group All 0 10V SLCs form a reliable secure and dynamic mesh network extending the range of the...

Page 5: ...MeshTek H52 Bluetooth 5 0 ready module Range of up to 200m with no external antenna required Real time clock for scheduling tasks 0 10V Analog or Single 10V PWM control signal 2 2 Package Contents Pac...

Page 6: ...PUT CONNECTOR J2 PROGRAMMING CONNECTOR 2 6 Benefits One 0 10V analog or 10V PWM control signal suitable for horticultural lighting control Stores up to 50 repeatable daily schedules such as ON OFF and...

Page 7: ...nel 1 AUX AUX 12V 24V Input Supply Current AUX 10mA 100mA With ilumi mesh stack running Analog Output Voltage Channel 1 DIM DIM 0 10V Default 0 10Vdc Can be configured to 10V PWM Radio Operating Frequ...

Page 8: ...7 J7 is available for connecting 0 10V Analog Output to an LED Driver J7 pinout with wire color for reference is as noted below Pin No 1 Green Wire Pin No 2 White Wire DIM DIM Note DIM DIM is by defau...

Page 9: ...arted It is recommended that a wrist band or anti electrostatic glove be used when handling the SLC 4 1 Connecting the 0 10V SLC to LED driver Application setup for LED driver with dimming functionali...

Page 10: ...e of the distributor under the Enterprise App section ilumi Solutions Inc 5 Tap to trust 6 Tap to confirm and now open Horticulture You can use the QR Code below to download iOS app as well Once regis...

Page 11: ...lutions com for white labelling the app and enhancements with additional features and functionality When the MeshTek App is launched click on I have MeshTek button we assume you have purchased a MeshT...

Page 12: ...p The app scans for the powered SLCs and initiates the commissioning pairing process Please see Figure 5 3 The maximum number of mesh SLCs that can directly connect with an iOS Android device is confi...

Page 13: ...the Group level and show all of the commissioned SLCs in this Group Scroll left to the Dashboard screen to control and vary brightness of individual channels as shown in last image of Figure 5 4 The...

Page 14: ...ting Defaults and Scenes A user can set a default or a scene by creating a specific setting on the Light Setting Screen for a Group or individual light Refer to Figure 5 5 and Figure 5 6 to do so The...

Page 15: ...user can set multiple scenes by clicking on the Scene Tab on the Light Setting Screen The scenes created can be accessed modified renamed deleted and run from the Scenes screen which can be navigated...

Page 16: ...process To create a schedule the user needs to be near the lights to be scheduled and the lights should be powered on and connected to the app 5 4 1 Click on the Group or individual light inside the G...

Page 17: ...shown in Figure 5 8 The user can then edit any parameter of the schedule or delete that schedule as well Please note that in order to remove the schedule from the SLC the user needs to be close to the...

Page 18: ...he driver ON OFF again Soft Reset Have the SLC ON and connected to the App On the Dashboard screen click on the Group name It will take you inside the group which consists of all paired SLC as shown i...

Page 19: ...Packaging MeshTek 1 Channel 0 10V SLC in a sealed antistatic bag Figure 6 1 Packaging 6 2 Packaging Label Figure 6 2 Packaging Label Company ilumi solutions Brand MeshTek SKU MTA1SLC Model MeshTek ML...

Page 20: ...ial Page 20 21 6 3 Ordering Information Ordering information for the MeshTek 1 Channel 0 10V SLC Part Number Description MTA1SLC MeshTek 1 Channel 0 10V SLC MTA4SLC MeshTek 4 Channel 0 10V SLC Note Fo...

Page 21: ...dated figure nos Updated table of content 1 3 Dec 2017 Added Lighting Controller color and brightness control screen 1 4 May 2018 Updated text in connector pinout section Updated electrical specificat...