The cooking hob is supplied as a natural gas unit and should not require any adjustment of the aeration. If
the appliance is ordered and specified as a ULPG gas then it will be converted by Eurolinx prior to
dispatch and should not require any adjustment to the aeration. Follow the steps below to convert to LPG
and to adjust the aeration of the burners. Remove the pan supports, caps and burners from the hob.
Remove the screws from under each burner that are securing the hob to the base and lift top up to gain
access to the burner venturie.
Note: Some models that do not have a one piece hob will have securing around the outside edge of the
spillage bowl that will also need to be removed to gain access to the underside of the cooking hob.
Remove screw “F” and remove air damper “R” Replace the Natural gas injector
that is located at entry point of the venturie “U” with the ULPG injector. Use the
chart below to identify the correct injector for each type of burner. Replace the
air damper “R” and refit screw “F” leave lose to allow adjustment of aeration.
adaptation to different types of gas
Buil
t-in cooktops
22
ILVE Built-in Cooktop Operating & Installation Manual