background image

8

EXTRACTOR HOOD

Dear Customer,
Thank you for buying our hood. Please read these instructions carefully 

for its optimum installation, use and maintenance.

Notes

: The figures mentioned in this manual are in the first pages.

This hood is designed for fitting in a cabinet or on some other support.

Warning:

 consult local regulations regarding fumes outlets. Do not 

connect the hood to a fume, ventilation or hot air duct. Confirm 

that  room  ventilation  is  appropriate  with  the  local  authorities. 

Make sure

the  maximum  air  extraction  flow  rate  for  the  appliances  in  the  room 

does  not  exceed  4  Pa  (0.04  mbar).The  room  must  have  adequate 

ventilation if an extractor hood is used simultaneously with appliances 

that  run  on  gas  or  other  fuels.  The  evacuated  air  must  be  extracted 

through ducts that are used for evacuating fumes from appliances that 

run on gas or other fuels. Regulations regarding air extraction must be 

complied with.
This product in intended for HOUSEHOLD USE only.
Use a rigid PVC pipe with a min. Ø l20 mm to evacuate fumes outside.
The above restrictions do not apply to hoods with no fumes outlet to outside

(recirculation system with activated charcoal filter).

Install the hood in line with the instructions on the template.
For  gas  cooking  appliances  only:  the  minimum  distance  to  the  hood 

must be  at least 65 cm.

Warning: 

Failure to install the screws or fixing device in accordance

with these instructions may result in electrical hazards.

INSTALLATION

The cooker hood is supplied with

 

3 Spacer (F, H)

 

4 Screws (C)

 

2 Bulbs

To fixing the Hood, use the 4 screws (C) Ø6mm supplied with the hood.

Close  the  space  that  remains  between  the  hood  and  the  wall, 

adjunsting the spacer (F).
Before  completing  any  connection,  make  sure  the  house  voltage 

corresponds with the voltage indicate on the data label.

Connecting the hood to the grid

Warning:

  before  connecting  the  hood:  switch  off  the  electricity 

supply  and  check  that  the  supplied  voltage  and  frequency 

coincide with that indicated on the appliance nameplate.

If  the extractor hood has a plug, connect it to a power socket in line 

with applicable regulations, located in an accessible area.
If  the hood does not have a plug, connect it directly to the electrical 

grid, protected by a separator device accessible for disconnection, in 

line with local regulations.
The connection to the electrical mains must be made as follows:

BLUE………………………..”N” NEUTRAL
BROWN……………………..”L” LIVE
GREEN AND YELLOW……(simbolo tierra) EARTH

If  the  terminals  of  the  plug  are  unmarked  or  if  you  are  in  any  doubt 

consult a qualified electrician.
If it is not supplied fit a plug normalized in the cord for the load showed 

on the rating plate.

USE OF THE HOOD – SAFETY
Warning: 

the  hood  may  stop  working  during  an  electrostatic 

discharge (e. g. lightning). This involves no risk of damage. Switch 

off  the  electricity  supply  to  the  hood  and  reconnect  after  one 

minute.

This appliance can be used by children aged from 8 years and above 

and  persons  with  reduced  physical,  sensory  or  mental  capabilities  or 

lack of experience and knowledge if they have been given supervision 

or  instruction  concerning  use  of  the  appliance  in  a  safe  way  and 

understand  the  hazards  involved.  Children  shall  not  play  with  the 

appliance.  Cleaning  and  user  maintenance  shall  not  be  made  by 

children without supervision. 

To  avoid the risk of fire, clean the metal filter regularly, permanently control 

pans containing hot oil and do not flambé food underneath the hood.

Do  not  use  the  hood  if  it  shows  signs  of  damage  or  imperfection. 

Contact an official distributor or authorised dealer.

Accessible parts may heat up when using cooking appliances.

Air Intake Speed (Fig 2)

The front panel has to be pulled its maximum extension so as to optimise 

the extraction capacity.

The three setting switch (C-2) has the following functions:

 

0 Stop

 

1 Low Speed

 

2 High Speed

Switch on the Lamps (C-1 Fig 2)
Pull out the grill (G) more than 50mm

SUCTION VERSION

If the hood is to be installed as a SUCTION hood, connect the plastic 

outlet  piece  (A)  supplied  with  the  hood  (120mm  diameter  pipe  for 

better performance and lower noise levels.

FILTERING VERSION (INTERNAL RE-CYCLING)

When  there  is  no  exhaust  duct  for  venting  out-door,  you  can  use  a 

carbon filter (D). The air is depurate by the filter and put again in the 

surrounding.
The air is released in the room through a connecting pipe, which goes 

through the hanging cupboard and us connected to the connecting 

ring supplied (A) Fig 1.

To use the appliance in this version, proceed as follows:

 

Open the grids (E)

 

To proceed to change the charcoal filter (D), the screw (B) 

has to be removed.
 

Reinstall the grids.

HOOD MAINTENANCE

Warning:

 always switch off the electricity supply before carrying 

out  maintenance  work  on  the  hood.  In  the  event  of  a  fault, 

contact an official distributor or authorised dealer.

Exterior cleaning: use non-corrosive, liquid detergent and avoid the use 

of abrasive cleaning products.

Grease filters: to avoid fires, clean thoroughly once a month. To do so, 

remove  the  filters  and  wash  with  hot  water  and  detergent.  If  using  a 

dishwasher,  position  the  filters  vertically  to  prevent  solid  remains  from 

depositing on them.

Activated charcoal filters: replace the every 2 months.

Important:

  increase  the  filter  cleaning/replacement  frequency  if  the 

hood is used for more than 2 hours a day. Always use genuine filters 

from the manufacturer.

Bulb replacement (look for the 

symbol in the figures)

Warning:

 do not handle the bulbs until the electricity supply has been 

switched off and they have cooled.

Important:

  use  new  bulbs  according  to  that  indicated  on  the 

hood nameplate.

Use  bulbs with an aluminium reflector to replace halogen bulbs. Do 

not use dichroic bulbs - risk of overheating.
On  cooker  hoods  equipped  with  tungsten  lamps,  the  lights  should 

only be used during operation of the motor. They should not be left on 

permanently and used as a light source.

Legal information

The manufacturer:
- Declares that this product meets all basic requirements regarding low-

voltage  electrical  equipment  established  in  Directive  2006/95/EC  of 

12  December  2006  and  electro-magnetic  compatibility  established  in 

Directive 2004/108/EC of 15 December 2004.

-  Is  not  responsible  for  any  failure  to  observe  the  instructions  given  in 

this  manual  and  current  safety  regulations  for  the  correct  use  of  the 

equipment.

- Reserves the right to make any modifications to the equipment or this 

manual without prior notice.

Contact  our official distributor should you require technical assistance 

or additional information on our products.

EN

Summary of Contents for CS Series

Page 1: ...INSTRUCTION MANUAL USER GUIDE FOR CS SERIES SLIDE OUT RANGE HOOD ...

Page 2: ......

Page 3: ...C1 C2 B G E F H D Fig 2 Fig F C1 C2 A C 42 280 180 600 700 900 553 653 853 453 553 753 280 37 210 40 231 ...

Page 4: ...44 ...

Page 5: ...olved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision To avoid the risk of fire clean the metal filter regularly permanently control pans containing hot oil and do not flambé food underneath the hood Do not use the hood if it shows signs of damage or imperfection Contact an official distributor or authorised dealer Accessib...

Page 6: ...id duct Avoid using a narrower duct than specified as this will reduce airflow the best performance is obtained when the range hood is installed with a short duct with minimal bends To determine the required clearance between the cooktop and the range hood always consult the installation manual for both the range hood and cooktop The required clearance is the greater of the distance specified in e...

Page 7: ...E product is defective by a factor other than a defect arising in the manufacture of the ILVE product including but not limited to ilve com au a damage through misuse including failure to maintain service or use with proper care neglect accident or ordinary wear and tear including deterioration of parts and accessories and glass breakage b use for purpose for which the ILVE product was not sold or...

Page 8: ... contravene the law of the relevant jurisdiction or ii cause any part of the Warranty to be void c ILVE excludes indirect or consequential loss of any kind including without limitation loss of use of the ILVE product and other than expressly provided for in these terms and conditions subject to all terms conditions and warranties implied by custom the general law the Act or other statute IMPORTANT...

Page 9: ... 4pm ilve com au NSW ACT Head Office 48 50 Moore Street Leichhardt F 02 8569 4699 VIC SA 1211 Toorak Road Camberwell F 03 9809 2155 QLD 1 42 Cavendish Road Coorparoo F 07 3397 0850 WA NT Unit 10 55 Howe Street Osborne Park F 08 9201 9188 TAS Crisp Ikin 3 Pear Avenue Derwent Park 7009 P 03 6272 7386 New Zealand PO Box 11 160 Sockburn Christchurch F 03 344 5906 ...

Reviews: