29
A
EN
Built-in vacuum drawer
42/2018 cod. EI33960040000EN
VM615
Troubleshooting
Problem
Cause
Solution
During a cycle
comes on, accompanied
by an audible signal.
• The vacuum is not activated.
The lid has not been closed.
• The vacuum is not activated.
There is dirt on the seal of the
lid.
• The vacuum is not activated.
The lid seal is broken.
• The pump won't start
The pump protection has been
activated.
• When the cycle has been started,
gently press the lid to activate the
vacuum.
• Clean the tray and the seal.
• Contact the Technical Support
service for replacement.
• In the bottom right of the packag-
ing machine, there are 2 buttons
(A)
that restore the internal pro-
tections. Press the keys to restore
the protections. If the fault recurs
contact the Technical Support
service.
During a cycle with ex-
ternal container
comes on accompanied
by an acoustic signal.
• The lid of the external contain-
er is not positioned correctly.
• The external suction device
was not properly connected.
• Correctly position the lid of the
external container.
• Correctly connect the external
suction device to the packaging
machine and to the container.
The cycle completes, the
symbol
flashes
along with an acoustic
warning.
• Vacuum sensor fault
• Contact the Technical Support
service.
It comes on
and
flashes
.
• Many consecutive cycles
were performed and the oil
in the pump has overheated.
• Cool the packaging machine for
at least 1 hour.