C O M M A N D R E F E R E N C E
Notes about Syntax
40
MPS-8033
C H A P T E R
4
!
LAS:POW
1
Used to set the optical output power.
LAS:POW?
NONE
Returns the output power in the selected display units.
LAS:REF
1
Used to set the reference power for dB mode.
LAS:REF?
NONE
Returns the reference power in the display units.
LAS:STEP
1
Used to set the DEC/INC step size.
LAS:STEP?
NONE
Returns the step size in the selected display.
MES
1
Used to enter a string of 16 ASCII bytes.
MES?
NONE
Returns a previously stored ASCII message.
MODE:DB
NONE
Commands the display units to dB.
MODE:DB?
NONE
Returns 1 if the display mode is dB.
MODE:DBM
NONE
Commands the display units to dBm.
MODE:DBM?
NONE
Returns 1 if the display mode is dBm.
MODE:W
NONE
Commands the display units to mW.
MODE:W?
NONE
Returns 1 if the display mode is mW.
MODE?
NONE
Returns the display units.
*OPC
Causes the 8033 to generate the
OPERATION COMPLETE
message in
the Standard Event Status Register when all pending overlapped
commands have been completed.
*OPC?
Places an ASCII character 1 into the 8033’s Output Queue when all
pending operations have been finished.
*PRE
Sets the parallel poll register enable bits.
*PRE?
Determine the contents of the
PARALLEL POLL ENABLE REGISTER
.
*PSC
Used to avoid any undesirable service requests when the 8033 is
powered up.
*PSC?
Queries the 8033’s power−on−status−clear flag.
*PUD
Stores data unique to the 8033.
*PUD?
Retrieves the contents of the *PUD storage area.
*RST
Performs a device reset.
SECURE
1
Used by service personnel to access to protected data.
*SRE
Sets the Service Request Enable Register bits to allow the 8033 to
generate the user−selectable service requests.
*SRE?
Determine the current contents of the Service Request Enable Register.
*STB?
Reads the Status Byte.
TERM
1
Sets the program message terminator.
TERM?
NONE
Returns the program message terminator.
TIME?
NONE
Returns the elapsed time since last powered up.
TIMER?
NONE
Returns the elapsed time since the timer was last reset.
*TST?
Initiates an internal self−test and returns a response when complete.
*WAI
Prevents the 8033 from executing any further commands until the No−
Operation−Pending flag is true.
Table 4.1
Command Reference
Name
Parameters
Expected
Function
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for MPS-8033 Series
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 9: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 11: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 13: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 23: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 53: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 103: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 107: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...