background image

 

Flextight Damaged Original Kit Instructions

Introduction

 

5

 

Introduction

 

The Flextight Damaged Original Kit will help you get better results 
when scanning scratched or otherwise damaged transparencies with 
your Imacon Flextight scanner. 

Normally, a primary advantage of Flextight is that it does not require 
any tape or gel when scanning transparencies. This saves you the time 
otherwise required to prepare and clean your originals and is also a 
result of the fact that no glass exists to interfere between your original 
and the scannerÕs CCD sensor. However, when working with damaged 
or scratched originals, the extreme sharpness of the Flextight scanner 
means that all of the damage to your original is accurately reproduced 
in your scan, thereby requiring you to retouch the original later.

When scanning a damaged original, scanning gel can actually work to 
beneÞt your scan. The gel Þlls the scratches of your original and acts to 
blur each scratch so that it takes on the color of the surrounding Þlm, 
thereby making the scratches much less visible.

The Flextight Damaged Original Kit makes it possible for you to use 
mounting gel when scanning with Flextight. Because scans are most 
typically made from new or well-preserved originals, most people will 
only need to use the kit occasionally.

Summary of Contents for Flextight Damaged Original Kit

Page 1: ...Instructions Flextight Damaged Original Kit...

Page 2: ...macon ApS Imacon ApS assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual Imacon ApS assumes no responsibility or liability for loss or damage incurred...

Page 3: ...al Kit Instructions Table of Contents 3 Table of Contents Introduction 5 Kit Contents 6 Included Materials 6 Additional Materials Required 7 Using the Kit 8 Preparing a Damaged Original for Scanning 8...

Page 4: ...Flextight Damaged Original Kit Instructions Table of Contents 4...

Page 5: ...ensor However when working with damaged or scratched originals the extreme sharpness of the Flextight scanner means that all of the damage to your original is accurately reproduced in your scan thereb...

Page 6: ...e original shown with an original mounted B Mounting Foils Two layer holders in which you will apply gel and insert an original C Roller Helps you to spread the gel evenly over the originals after app...

Page 7: ...Fluid This should simply be the standard cleaning uid used for cleaning originals after drum scanning with gel The manu facturer of the gel included with the cleaning kit Policrom Screens markets such...

Page 8: ...hat you can open the foil from the bottom The top of the foil must lie straight along the top of the clasp 3 Open the foil 4 If you have not already done so break the seal on the gel tube and or attac...

Page 9: ...ing the applicator cap To store the gel for a longer period of time remove the applicator and replace the tube cap Cleaning the Original 1 Remove the foil from the Flextight original holder 2 Remove t...

Page 10: ...Flextight Damaged Original Kit Instructions Using the Kit Cleaning the Original 10...

Reviews: