Imacon Flextight Photo UserÕs Guide
Hardware ReferenceÑFlextight Photo
Cleaning the External Surface of the Scanner
17
English
3.
Use the allen key that came with your scanner to remove the
screws located at each of the four corners of the bottom panel of the
scanner. Remove the bottom panel and put it and the screws aside.
4.
The lamp is clearly visibleÑit is the long tube immediately behind
the bottom panel. Hold each end of the lamp between your thumb
and index Þnger. Rotate the lamp until it comes free and pull it
away from the scanner. Note that the lamp sockets allow the tube
to be rotated all the way around, but they click into position at each
quarter turn. The lamp is locked in place in all but one of these four
positions, so you may need to try up to three positions before the
lamp comes free.
5.
Install a new lamp following the reverse of the procedure you used
to remove it. Make sure the sleeve is aligned correctly with the
scanner as shown in Figure 4. Rotate the lamp and/or adjust the
sleeve as necessary.
6.
Replace the bottom panel.
Cleaning the External Surface of the Scanner
If the external surface of the scanner becomes dirty, then clean it with a
damp cloth. Be careful not to get any moisture inside the scanner or on
any of the connectors. Do not use alcohol or other solvents.
Disposal
If you need to dispose of the scanner, it must be delivered to the local
waste plant.