C.3
Recovery Function
The recovery function resets all parameters of the device to factory defaults after a fatal
system breakdown.
The recovery key is necessary to invoke the recovery procedure. The key is delivered with
every device. It is marked with the label
Recovery
.
Important:
The recovery function resets the IP address to the factory default value of
192.168.1.50. If the scanner had a different IP address, it will be necessary
to use the cross over cable and change the network settings on the local
computer.
C.3.1
Important Notes before recovering to Factory Defaults
Write down the values for IP address, subnet mask and gateway of the device before
starting the recovery sequence.
The recovering to factory defaults described in the following should
only
be executed after
a fatal system breakdown!
After recovering to factory default,
all
firmware updates
have to be executed! Make sure
an update file is available on the local computer.
After recovering to the factory defaults,
all
adjustment procedures
described in the
previous sections have to be executed again!
C.3.2
How to Recover to Factory Defaults
1. Power down the device.
2. Plug the recovery key into the serial port at the rear panel of the device.
Picture 81: Connectors on rear panel
3. Power the device up via the start button.
Setup and Assembly Manual
Page 69