Page 90
Setup Manual
E.1.2
How to Recover to Factory Defaults
Important:
The scanner must be in stand-by mode before inserting the recovery key.
Picture 74: Connectors on the WideTEK 25
1. Main power
switch
2. Network cable
connector
3. External power
supply connector
4. Foot pedal
connector
5. Serial port /
Recovery key
connector
6. VGA and DVI
video output
connector
Plug the recovery key into the
Recovery key connector
(detail 5 in the above picture) at
the connector panel.
Push the on/off button in the front panel to start the scanner.
The device will start and, after it has found the recovery key to be present in the port, it will
automatically execute the recovery sequence. All viable system data will be restored and
necessary repair steps will be taken without the need of any user interaction.
Note:
The recovery sequence can last some minutes. While the recovery sequence
is running,
no message
will be displayed.
When the recovery sequence has finished, the device will power down automatically.
Important:
Do not switch off the device at any time during the recovery procedure!
•
Unplug the recovery key after the device has powered down.
•
Power up the device and launch the scan application in your browser.
The IP address of the device has the factory default value: 192.168.1.50