To drain the hydrotherapy spa, follow the steps below:

1. Using the console, adjust the temperature to the

lowest setting.

2. Shut off the power to the spa, at the circuit breaker

or GFCI.

3. Remove the access panel from the spa (see

ATTACHING AND REMOVING THE ACCESS

PANEL on page 14).

4. Pull the hose out and hold it above the waterline.

Remove the cap, open the valve knob, and attach

a garden hose to the drain hose. Lower the hose

and drain the spa.

5. When the spa is empty, remove the garden hose,

close the valve knob, and re-attach the cap and

return the drain hose inside the spa.

6. Re-attach the access panel.

7. Refill the spa and treat the water with chemicals

(see pages 10 and 14).

DRAINING THE PUMPS

After the hydrotherapy spa is drained, the jet pumps

should also be drained if the spa will be stored for

more than thirty days or if it may be exposed to freez-

ing temperatures.

Turn off the power to

the spa. To drain the jet

pumps, remove the

access panel from the

spa unit (see ATTACH-

ING AND REMOVING

THE ACCESS PANEL

on page 14). Locate

the jet pumps inside

the spa. Loosen the

indicated collar on each of the pumps.

WINTER USE AND CARE

The hydrotherapy spa is designed for year-round use.

If you decide to store the spa for the winter, store it in

a warm, dry location. Follow the steps below to winter-

ize the spa.

1. Make sure the power to the spa is turned off.

2. Drain the spa (see DRAINING THE HYDROTHER-

APY SPA on the previous page and this page).

3. Remove all remaining water from the spa shell. Dry

the spa shell with towels.

4. Set the air controls to the lowest setting. Use a

wet/dry vacuum to pull any remaining water from

the system. To do this, place the vacuum nozzle

over each jet, starting with the highest jet and fin-

ishing with the lowest jet.

5. Set the air controls to the highest setting and

repeat step 3.

6. Drain the pumps (see DRAINING THE PUMPS on

this page). Once the water is drained from the

pumps, place the vacuum nozzle over the drainage

hole in the pumps and vacuum any additional

water from the pumps.

Note: For additional pro-

tection, remove the pumps/motors from the spa

and store them in a climate-controlled room.

7. Clean the spa shell (see page 13).

8. Clean the filter (see page 13).

9. Shut the power off at the breaker.

Label the

breaker in such a way that the breaker will not

be turned on accidentally.

10. Re-attach the access panel and the spa cover.

REPLACING THE LIGHT BULB

If the underwater light burns out, you will need to

remove the access panel to replace it (see ATTACHING

AND REMOVING THE ACCESS PANEL on page 14).

Make sure the spa power is turned off. Next, locate the

light housing. Turn the light housing counterclockwise

and remove it from the spa shell.

To replace the light bulb, pull the old light bulb out of

the housing and insert a new light bulb. Re-attach the

light housing to the spa shell. Re-attach the access

panel to the spa.

Collar

Drain

Hose

Valve

Knob

Cap

Light Housing

Light

Housing

Light

Bulb

Summary of Contents for IMSB73920

Page 1: ...provide immediate assistance free of charge CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 8 a m 5 p m CST Model No IMSB73920 IMSG73920 Serial No The serial number is on a sign behind the access panel Writ...

Page 2: ...Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all users...

Page 3: ...nt damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into the hydrotherapy spa t...

Page 4: ...eir physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be seriously harmed This is especially important du...

Page 5: ...SE INSTRUCTIONS water with relatively high pressure Prolonged exposure of a localized area of the body may cause bruises to the skin 36 The included warning sign must be posted where all users of the...

Page 6: ...your best For your benefit read this manual carefully before using the IMAGE RENEW 739 If you have ques tions after reading the manual please call our Customer Service Department toll free at 1 877 89...

Page 7: ...the spa provided you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa I...

Page 8: ...s Read each assembly step before you begin Tighten all parts as you assemble them unless instructed to do otherwise ASSEMBLY REQUIRES THE FOLLOWING TOOLS not included One phillips screwdriver A wire c...

Page 9: ...gh or low positions 4 The hydrotherapy spa operates on a 240 volt power source and must be wired directly to a 240 volt Ground Fault Circuit Interrupter GFCI installed in your home This procedure must...

Page 10: ...proper water maintenance STARTING THE HYDROTHERAPY SPA You should always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the jet button on the console see USING THE C...

Page 11: ...ce G An optional ozone generator can be purchased and installed to utilize the ozone jet Ozone helps sani tize the spa with minimal chemical treatment H The console controls the spa jets turns the und...

Page 12: ...mode that heats and filter the water when the spa is left unattended When the power to the spa is first turned on or if the water temperature is below the set temperature the water will be heated as r...

Page 13: ...spa should always be clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover use water and a non abrasive cleaner on the en...

Page 14: ...Proper water maintenance is a com plex process Contact your local pool and spa supplier for information concerning which chemicals you should use in your area to sanitize the spa CHANGING THE FILTER...

Page 15: ...the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 3 Remove all remaining water from the spa shell Dry the spa shell with towels 4 Set the air controls to the lowest settin...

Page 16: ...the air control to low The water will heat at a rate of 6 F per hour If you are using the spa indoors and the room temperature is main tained at 70 F it will take approximately 6 to 8 hours for the w...

Page 17: ...ce the damaged seal b Some water loss due to evaporation is normal If rapid water loss occurs or if you notice wet ness on the floor around the hydrotherapy spa the spa shell may have a leak Contact y...

Page 18: ...ew 28 8 1 4 x 1 1 2 Screw 29 1 Console With Overlay 30 1 Whirlpool Jet 31 8 1 4 Washer 32 1 Face Plate Assembly 33 3 Panel 34 2 Heater Collar With Screw 35 1 Volcano Jet 36 3 Nozzle Housing 37 21 Smal...

Page 19: ...8 23 31 13 20 1 12 2 15 37 43 44 36 40 39 41 42 41 38 35 46 46 46 46 33 6 6 9 47 45 48 45 48 14 9 9 30 52 50 50 17 17 17 17 53 53 23 31 49 4 23 31 23 31 4 7 8 34 34 54 51 5 22 3 21 16 24 32 Exploded D...

Page 20: ...e following incidents any damage to the premium cedar surround or frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resulti...

Reviews: