background image

ties. Also, if the water temperature falls below 40¡F,
the pump will begin circulating and heating the water
to prevent the water from freezing.

DRAINING THE RENEW 815

To drain the RENEW 815, you must use a garden
hose to siphon the water. Place one end of the hose
in the RENEW 815 and hold it in front of a hydro-
therapy jet until there is a flow of water coming out of
the hose. 

Turn off the spa unit and unplug the

power cord. The unit will be damaged if it is run
without water circulating.

Be sure the end of the

hose in the RENEW 815 is on the floor of the spa. 

DRAINING THE PUMP

After the RENEW 815 is drained (see DRAINING
THE RENEW 815 above), the pump in the dry side jet

pack should also be drained if the RENEW 815 will be
stored for more than thirty days, or if it may be
exposed to freezing temperatures. To drain the pump,
follow these steps:

¥ Remove the pillow from the wet side jet pack
¥ Unscrew the two threaded collars (see assembly

step 4) connecting the dry side jet pack to the wet
side.

¥ Remove the filter cap 
¥ Remove the six screws securing the dry side shell

(15) to the dry side jet pack. 

¥ Locate the pump inside the spa jet unit. 
¥ The nut on one side of the pump must be

unscrewed and the unit must be tipped on its side

¥ Rock the spa jet unit slightly, until all the water has

drained from the pump. 

¥ Replace the nut on the pump
¥ Replace the dry side shell, filter cap and pillow

12

USING THE CONSOLE

Refer to the console diagram at the right. The function
of each console control is explained below:

Thermostat:

Controls the temperature of the water.

The thermostat can be set to heat the water from
70¡F to 104¡F. Use a medical or other accurate ther-
mometer to check the temperature of the water.

On/Off Button:

Turns the spa jet unit on and off and

changes the operation mode of the spa. The spa has
three modes of operation:
¥ Auto Heat
¥ Soak
¥ Hydrotherapy
When your spa is in the auto heat mode, pushing the
button once will cause it to go into soak mode for 20
minutes. Pushing the button twice will cause the spa
to go into hydrotherapy mode (the jets will be running)
for 20 minutes. If your spa is not heating, pushing the
button once will cause it to go into hydrotherapy
mode. Pushing the button again will switch to soak
mode.

The spa jet unit also features an automatic mode,
which heats and filters the water when the spa is left
unattended. When the spa jet unit is first plugged in,
or if the on/off button on the console has not been
pressed for longer than three hours, the automatic 

mode will begin filtering or heating the water, as need-
ed. 

Note: To keep the filter and heat cycles from

running, the power cord must be unplugged.

The On/Off button has a built-in delay factor. The
spa will turn on 5 to 10 seconds after the button is
pressed.

Thermostat

On/Off Button

Summary of Contents for 815inflatable

Page 1: ...EE CUSTOMER HOT LINE The trained techni cians on our customer hot line will provide immediate assis tance free of charge to you CUSTOMER HOT LINE 1 800 999 3756 Mon Fri 6 a m 6 p m MST Model No IMHS81...

Page 2: ...d in the center of this manual 2 Table of Contents The decals shown below have been placed on the RENEW 815 If a decal is missing or if it is not legible please call our Customer Service Department to...

Page 3: ...gned to support weight 11 Remove any water that may collect on the spa cover 12 Keep children and pets away from the RENEW 815 when it is not in use 13 Keep all chemicals away from children and pets 1...

Page 4: ...child could be seriously harmed 27 DANGER To reduce the risk of drowning Prolonged immersion in the RENEW 815 may cause hyperthermia a dangerous condition which occurs when the internal body temper a...

Page 5: ...through Friday 6 a m until 6 p m Mountain Time excluding holidays To help us assist you please note the product model number and serial number before calling The model number is IMHS81592 The serial...

Page 6: ...r of the tub is 63 You should allow for this size plus the size of the spa jet unit plus room to remove the cover when choosing the location 8 Be sure to note any other considerations such as aestheti...

Page 7: ...urround 9 Start the flap where the fastener strip starts and pull the flap tight as you go around Make sure the three holes in the Inflatable Liner are centered in the cutout in the Spa Surround 9 as...

Page 8: ...Inflatable Liner 29 Slide a Wet Side Gasket 48 onto each connector Firmly tighten a Wet Side Nut 49 onto each con nector 4 Position the wet side jet pack B as shown Place an O ring 52 in the groove of...

Page 9: ...important to smooth out as many wrinkles as possible Resume filling the spa until the water reaches the fill line Do not overfill the spa Note When the spa is filled the Spa Surround 9 may bow slightl...

Page 10: ...with a Ground Fault Circuit Interrupter GFCI located at the end of the power cord You should always test the GFCI before using the RENEW 815 First turn on the RENEW 815 by pressing the power button on...

Page 11: ...60 to 64 F SECURING THE SPA COVER The spa cover can be secured by snapping the latch es on the spa cover into the buckles on the wood sur round The buckles can be locked by inserting the key and turni...

Page 12: ...rained from the pump Replace the nut on the pump Replace the dry side shell filter cap and pillow 12 USING THE CONSOLE Refer to the console diagram at the right The function of each console control is...

Page 13: ...5 Keep all containers closed tightly when not in use 6 Never add water to the chemicals always add the chemicals to the water as directed 7 Always store chemicals in a cool dry place 8 Always keep ch...

Page 14: ...the water should heat Cover the RENEW 815 with the spa cover The spa cover must be tight The water will heat at a rate of 1 3 F an hour If you are using the spa indoors and the room tem perature is ma...

Page 15: ...be kept outdoors in cold weather you must allow the spa to maintain a safe temperature by running in automatic mode Allowing the spa jet unit to freeze will damage the unit If you do not want to use t...

Page 16: ...ill take 1 to 3 days depending on the room temperature to heat the water in the spa The good news is that once the water is heated it will maintain its tempera ture for a relatively low cost You can r...

Page 17: ...eater Pump Gasket 41 2 Wire Tie 42 5 Snap in Fastener 43 4 Filter Housing Screw 44 1 Index Washer 45 1 Surround Bottom 46 1 Temperature Probe Gasket 47 1 Temperature Probe Nut 48 2 Wet Side Nut 49 2 W...

Page 18: ...1 33 36 20 36 35 5 5 15 5 5 5 8 28 2 26 18 18 38 38 19 10 25 29 9 13 6 42 42 42 42 43 10 14 21 24 12 40 43 44 41 42 27 27 17 7 51 50 51 50 3 30 45 48 49 49 48 32 46 47 36 36 34 52 EXPLODED DRAWING Mod...

Page 19: ...sed by or attributable to the following incidents any dam age to the wood exterior resulting from improper maintenance or any damage to the wood or tile exterior attributable to freight mishandling da...

Reviews: