background image

8

2. Orient the dry side jet pack (A) as shown and place

it near the three holes in the Inflatable Liner (29). 

Slide the Temperature Probe Gasket (46) over the
connector threads on the Temperature Probe
Assembly (30). Insert the wire (not shown) through
the 

small

hole in the Inflatable Liner (29) and then

push the Temperature Probe Assembly into the hole.

Make sure that the threads on the connector are
pushed fully through the vinyl liner.

Firmly tighten

the Temperature Probe Nut (47) onto the connector
threads. Connect the wire from the Temperature
Probe to the receptacle on the dry side jet pack (A).

3. Move the dry side jet pack (A) against the wall of the

tub. Pull the two connectors on the dry side jet pack
through the large holes in the Inflatable Liner (29).
Slide a Wet Side Gasket (48) onto each connector.
Firmly tighten a Wet Side Nut (49) onto each con-
nector.

4. Position the wet side jet pack (B) as shown. Place

an O-ring (52) in the groove of each connector on
the wet side jet pack.

Make sure that the O-rings

are positioned securely in the grooves, as shown
in drawing 4A.

Attach the threaded collar on the right side (as seen
on drawing 4A) of the wet side jet pack (B) to the
corresponding connector on the dry side jet pack
(A). Attach the left side in the same manner.

Important: If the threaded collars are not fully
tightened, the spa will not function.

Position the Pillow (26) over the hole in the top of
the wet side jet pack (B). Push the fasteners on the
Pillow through the appropriate holes in the wet side
jet pack.

2

A

46

30

Small

Hole

Receptacle

47

9

29

3

A

29

48

48

49

9

Connectors

4

A

B

26

29

O-rings (52)

4A

O-rings (52)

Threaded Collar

View of Inside of Wet Side Jet Pack

Summary of Contents for 815inflatable

Page 1: ...EE CUSTOMER HOT LINE The trained techni cians on our customer hot line will provide immediate assis tance free of charge to you CUSTOMER HOT LINE 1 800 999 3756 Mon Fri 6 a m 6 p m MST Model No IMHS81...

Page 2: ...d in the center of this manual 2 Table of Contents The decals shown below have been placed on the RENEW 815 If a decal is missing or if it is not legible please call our Customer Service Department to...

Page 3: ...gned to support weight 11 Remove any water that may collect on the spa cover 12 Keep children and pets away from the RENEW 815 when it is not in use 13 Keep all chemicals away from children and pets 1...

Page 4: ...child could be seriously harmed 27 DANGER To reduce the risk of drowning Prolonged immersion in the RENEW 815 may cause hyperthermia a dangerous condition which occurs when the internal body temper a...

Page 5: ...through Friday 6 a m until 6 p m Mountain Time excluding holidays To help us assist you please note the product model number and serial number before calling The model number is IMHS81592 The serial...

Page 6: ...r of the tub is 63 You should allow for this size plus the size of the spa jet unit plus room to remove the cover when choosing the location 8 Be sure to note any other considerations such as aestheti...

Page 7: ...urround 9 Start the flap where the fastener strip starts and pull the flap tight as you go around Make sure the three holes in the Inflatable Liner are centered in the cutout in the Spa Surround 9 as...

Page 8: ...Inflatable Liner 29 Slide a Wet Side Gasket 48 onto each connector Firmly tighten a Wet Side Nut 49 onto each con nector 4 Position the wet side jet pack B as shown Place an O ring 52 in the groove of...

Page 9: ...important to smooth out as many wrinkles as possible Resume filling the spa until the water reaches the fill line Do not overfill the spa Note When the spa is filled the Spa Surround 9 may bow slightl...

Page 10: ...with a Ground Fault Circuit Interrupter GFCI located at the end of the power cord You should always test the GFCI before using the RENEW 815 First turn on the RENEW 815 by pressing the power button on...

Page 11: ...60 to 64 F SECURING THE SPA COVER The spa cover can be secured by snapping the latch es on the spa cover into the buckles on the wood sur round The buckles can be locked by inserting the key and turni...

Page 12: ...rained from the pump Replace the nut on the pump Replace the dry side shell filter cap and pillow 12 USING THE CONSOLE Refer to the console diagram at the right The function of each console control is...

Page 13: ...5 Keep all containers closed tightly when not in use 6 Never add water to the chemicals always add the chemicals to the water as directed 7 Always store chemicals in a cool dry place 8 Always keep ch...

Page 14: ...the water should heat Cover the RENEW 815 with the spa cover The spa cover must be tight The water will heat at a rate of 1 3 F an hour If you are using the spa indoors and the room tem perature is ma...

Page 15: ...be kept outdoors in cold weather you must allow the spa to maintain a safe temperature by running in automatic mode Allowing the spa jet unit to freeze will damage the unit If you do not want to use t...

Page 16: ...ill take 1 to 3 days depending on the room temperature to heat the water in the spa The good news is that once the water is heated it will maintain its tempera ture for a relatively low cost You can r...

Page 17: ...eater Pump Gasket 41 2 Wire Tie 42 5 Snap in Fastener 43 4 Filter Housing Screw 44 1 Index Washer 45 1 Surround Bottom 46 1 Temperature Probe Gasket 47 1 Temperature Probe Nut 48 2 Wet Side Nut 49 2 W...

Page 18: ...1 33 36 20 36 35 5 5 15 5 5 5 8 28 2 26 18 18 38 38 19 10 25 29 9 13 6 42 42 42 42 43 10 14 21 24 12 40 43 44 41 42 27 27 17 7 51 50 51 50 3 30 45 48 49 49 48 32 46 47 36 36 34 52 EXPLODED DRAWING Mod...

Page 19: ...sed by or attributable to the following incidents any dam age to the wood exterior resulting from improper maintenance or any damage to the wood or tile exterior attributable to freight mishandling da...

Reviews: