background image

1.

Before beginning assembly, make sure that you
have read and understand the information in the
box above and on the previous page.

Remove the four screws from the access cover on
the console side of the spa. Remove the access
cover by sliding it down and then pulling the bottom
of it away from the spa. 

Be careful not to damage

the Spa Shell (15).

Remove the Power Cord with the GFCI (9) from
inside the spa.

2. Close the valve knob on the drain hose. Tighten the

two pump fittings.

Refer to step 1 above. Re-attach the access cover
with the for screws.

3. Remove the warning decals (not shown) from the

Spa Shell (15). Using a damp cloth, wipe the Spa
Shell clean. 

Before filling the spa, make sure that

it is in the desired position and that there is
room to easily service the spa. Once the spa is
filled, it will have to be drained before it can be
moved.

Using a garden hose or other clean water source,
begin filling the spa. 

Do not use soft water.

The

spa may be filled with cold water; however, if warm
or hot water is used, the spa will be ready for use
sooner. Fill the spa until the water is at the level
shown at the right. 

Do not overfill the spa.

SET-UP AND ASSEMBLY

Before beginning assembly, carefully read the
following information and instructions:

¥ Place all parts of the spa in a cleared area and

remove the packing materials from the spa shell;
do not dispose of the packing materials until
assembly is completed. 

¥ Assembly requires two people.

¥ Read each assembly step before you begin. 

¥ During assembly, make sure that all parts are

turned as shown in the drawings. 

TOOLS REQUIRED (not included):  

¥  One Phillips screwdriver

Fill to here

15

Screws

Console

15

9

1

Pump

Fittings

2

3

8

Access

Cover

Valve Knob

11

Drain Hose

Screws

Summary of Contents for IMHS20700

Page 1: ...QUESTIONS PLEASE CALL DIRECT TO OUR TOLL FREE CUSTOMER HOT LINE The trained technicians on our customer hot line will provide immediate assistance free of charge to you CUSTOMER HOT LINE 1 877 897 74...

Page 2: ...RENEW 207 7 SET UP AND ASSEMBLY 8 POSTING THE WARNING SIGN 10 USING THE RENEW 207 10 MAINTENANCE 13 TROUBLE SHOOTING 16 PART LIST 18 EXPLODED DRAWING 19 ORDERING REPLACEMENT PARTS Back Cover LIMITED H...

Page 3: ...spa shell can reach temperatures as high as 150 F in a matter of minutes if exposed to the sun while it is empty These high temperatures can cause significant damage such as blistering of the shell s...

Page 4: ...chil dren Children must always be supervised 28 DANGER To reduce the risk of drowning Never use the RENEW 207 alone Children should not use the spa unless they are supervised by an adult Keep pets aw...

Page 5: ...of 35 or persons with pre existing health problems such as obesity heart disease high or low blood pressure circulatory prob lems or diabetes to consult their physician before using the RENEW 207 38 W...

Page 6: ...al to the healing process and the powerful massage action eases tension and stress throughout the body The RENEW 207 gives you the specialized treatment you need to feel your best For your benefit rea...

Page 7: ...m that is built flush with the top of the spa provided you leave access to the motor for ser vice 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the...

Page 8: ...vice the spa Once the spa is filled it will have to be drained before it can be moved Using a garden hose or other clean water source begin filling the spa Do not use soft water The spa may be filled...

Page 9: ...t the Spa Cover is centered Snap a Buckle 2 onto each of the eight latches on the Spa Cover 13 Pull down one of the straps on the Spa Cover 13 and hold the Buckle 2 against the side of the spa Note To...

Page 10: ...becomes damaged There is a Ground Fault Circuit Interrupter GFCI on the end of the power cord Always test the GFCI before using the RENEW 207 First turn on the RENEW 207 by pressing the pump control...

Page 11: ...F per hour with the cover on If you are using the spa indoors and the room temperature is maintained at 70 F it will take approximately 10 to 20 hours for the water to reach the set temperature The te...

Page 12: ...usted for a custom water massage One of the jets focuses a water massage on your lower back a second jet focuses a water massage on your upper back and a third jet near the floor of the spa focuses a...

Page 13: ...ng moved or stored MAINTAINING THE SPA EXTERIOR The WeatherWood surround has been treated at the factory For information and supplies to maintain the beauty and color of your WeatherWood sur round cal...

Page 14: ...n be obtained at a pool and spa supply store The pH reading should be between 7 2 and 7 8 If the level is too low add a pH increaser usually soda ash If the level is too high add a pH reducer usually...

Page 15: ...SE AND CARE The RENEW 207 is designed for year round use If you decide to store the spa for the winter store it in a warm dry location Follow the steps below to winterize the spa 1 Drain the spa see D...

Page 16: ...cal spa and pool service provider 6 SYMPTOM THE WATER DOES NOT HEAT a The pump in the spa jet unit is the heater If the pump is operating the water should heat Cover the RENEW 207 with the spa cover T...

Page 17: ...u notice wet ness on the floor around the RENEW 207 the spa shell may have a leak Contact your local spa and pool service provider for repairs b A clamp or seal inside the pump compartment may be loos...

Page 18: ...ar Screw 18 1 Heater Terminal Cover 19 1 Filter Wrench 20 1 Filter Cover 21 1 Filter 22 2 Suction Cover Screw 23 2 Suction Cover 24 1 Thermostat Assembly Key No Qty Description 25 2 Power Supply Mount...

Page 19: ...32 26 5 1 2 3 4 6 11 13 15 2 14 16 28 29 37 7 19 20 21 12 9 25 22 23 30 31 39 24 27 42 34 33 18 41 35 8 10 10 17 17 40 43 43 40 36 40 38 3 4 EXPLODED DRAWING Model No IMHS20700 R0300A 19...

Page 20: ...sed by or attributable to the following incidents any damage to the WeatherWood surround or steel frame attributable to improper handling or freight dam age damage resulting from improper winterizatio...

Reviews: