WATER CHEMISTRY

The hydrotherapy spa comes with a starter chemical
pack for maintaining the water in the spa. (See TEST-
ING AND TREATING THE WATER on page 10.)
Additional chemicals can be purchased at a pool and
spa supply store.

CAUTION: The chemicals used to maintain the pH
balance of the water and to sanitize the water can
be dangerous. Always follow these basic guide-
lines when handling the chemicals:
1. Always read and follow the directions on the

label, unless directed otherwise.

2. Never mix different chemicals.
3. Do not exceed the recommended amounts of

chemicalsÑfollow the directions on the label
closely.

4. Keep all chemicals out of the reach of children

and pets.

5. Keep all containers closed tightly when not in

use.

6. Never add water to the chemicalsÑalways add

the chemicals to the water as directed.

7. Always store chemicals in a cool, dry place.

MAINTAINING THE PROPER PH BALANCE

The pH factor is a measure of the relative acidity or
alkalinity in the water. It is measured on a scale of 1
to 14. Pure water has a value of 7, which is neutral.
Any value above 7 is alkaline, and any value below 7
is acidic. You should maintain a slightly alkaline pH
level, between 7.2 and 7.8, in the hydrotherapy spa. 

Severe problems can occur when the pH balance is
not maintained within this range. If the pH level
exceeds 7.8, dissolved minerals can build up and clog
the plumbing in the spa jet unit. If the pH level falls
below 7.2, the acid level in the water will begin to cor-
rode the metal parts in the spa jet unit. Also, the sani-
tation agents in the water will not be effective if the pH
level is not properly maintained. Damage caused by
improper pH levels is not covered under the warranty.

To maintain the proper pH level, you should test the
pH of the water regularly. To test the water, you can
either purchase additional test strips or purchase a pH
test kit at a pool and spa supply store. The pH read-
ing should be between 7.2 and 7.8. If the level is too
low, add a pH increaser (usually soda ash). If the
level is too high, add a pH reducer (usually sodium
bisulfate). Test the water again after five minutes. See
the instructions with your pH test kit for additional
information about testing and adjusting the pH.

ATTACHING AND REMOVING THE ACCESS PANEL

To locate the access panel, refer to the drawing on
page 6. To remove the access panel, first remove the
four indicated screws. Slide the access panel down
and then pull the bottom of it away from the spa. 

Be

careful not to damage the spa shell as you
remove the access panel.

To replace the access panel, insert the top of the
access panel under the edge of the spa shell. Slide
the cover up until the bottom of the access panel
clears the trim along the bottom of the spa. Then,
slide the access panel into place and re-attach the
four screws.

DRAINING THE HYDROTHERAPY SPA

The hydrotherapy spa should be drained at least four
times a year and refilled with clean water. You may
need to drain the spa more often, depending on the
user load. This must be done because after repeated
chemical treatment the water becomes chemically
saturated. Once this happens, additional chemical
treatment of the water is no longer effective. The spa
should also be drained if you will not be using it for
long periods of time. The spa must always be drained
before major repairs are made.

The hydrotherapy spa should always be covered
when it is empty. Direct sunlight can cause exten-
sive damage. The surface of the spa shell can
reach temperatures as high as 150¡F in a matter
of minutes if exposed to the sun while it is empty.
These high temperatures can cause significant
damage, such as blistering of the shell surface
and warping of the spa shell. Any damage caused
by sun exposure is not covered under warranty.

Screws 

Access

Panel 

Summary of Contents for IMHS45590

Page 1: ...our customer hot line will provide immediate assis tance free of charge to you CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 6 a m 6 p m MST Model No IMHS45590 Serial No The serial number is found on a pl...

Page 2: ...6 Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all user...

Page 3: ...se high temperatures can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not brin...

Page 4: ...over when the spa is not in use 29 WARNING To reduce the risk of injury The water temperature should never exceed 104 F Temperatures between 100 F and 104 F are considered to be safe for healthy adult...

Page 5: ...e included warning sign must be posted where all users of the hydrotherapy spa can see and read it See POSTING THE WARNING SIGN on page 2 40 The causes symptoms and effects of hyper thermia may be des...

Page 6: ...your best For your benefit read this manual carefully before using the RENEW 455 If you have additional ques tions please call our Customer Service Department toll free at 1 877 897 7493 Monday throu...

Page 7: ...he spa provided you leave access to the motor for ser vice 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the hydrot...

Page 8: ...drawings Read each assembly step before you begin Tighten all parts as you assemble them unless instructed to do otherwise ASSEMBLY REQUIRES THE FOLLOWING TOOLS not included One 1 phillips screwdriver...

Page 9: ...s on the Inflatable Cover 4 Attach the latch on the strap to the buckle on the other end of the strap Make sure that the cutout in the Inflatable Cover is lined up with the warning label on the Spa Co...

Page 10: ...ges of QUICK pHix It DOWN and QUICK pHix It UP However the directions on the bottle of Non chlorine Shox and Bromine Base are correct Always keep the chemi cals away from children and pets The first t...

Page 11: ...r operate the spa without the suction covers in place G The air control determines the amount of air flowing through the spa jets during operation see USING THE CONTROLS on page 12 H The filter can be...

Page 12: ...plugged in or if the buttons on the console have not been pressed for longer than twenty minutes the automatic mode will begin filtering or heating the water as needed Note To keep the filter and heat...

Page 13: ...ays be clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover use water and a non abrasive cleaner on the entire cover Rins...

Page 14: ...water you can either purchase additional test strips or purchase a pH test kit at a pool and spa supply store The pH read ing should be between 7 2 and 7 8 If the level is too low add a pH increaser...

Page 15: ...the spa 1 Drain the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 2 Remove all remaining water from the spa shell Dry the spa shell with towels 3 Set the air control to the...

Page 16: ...e set temper ature b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See the chart below for the approximate heating time Air TemperatureHeating Time 70 F 16 to...

Page 17: ...ydrotherapy jets can be closed and opened by pushing and pulling the nozzles If no air flows through the hydrotherapy jets when the air control is turned counterclock wise simply pull the nozzles slig...

Page 18: ...ws 16 1 Filter 17 2 10 x 1 1 4 Screw 18 2 Suction Cover 19 1 Locking Ring 20 1 Pump Motor 21 1 Pump Motor Power Cord 22 1 Rubber Grommet 23 1 Light Cover 24 4 5 16 Lock Washer 25 1 Diverter Knob 26 3...

Page 19: ...19 18 17 11 5 4 22 35 25 33 19 15 8 16 7 2 7 9 10 26 18 31 30 34 23 3 10 33 32 29 26 10 24 5 12 21 14 6 13 28 27 20 6 12 13 1 Exploded Drawing Model No IMHS45590 R0300A...

Page 20: ...ng incidents any damage to the wood exterior resulting from improper maintenance or any damage to the wood or tile exterior attributable to freight mishandling damage resulting from improper winteriza...

Reviews: