The hydrotherapy spa is designed to seat five adults.
The spa holds 225 gallons of water and offers a heat-
ing system (70°F to 104°F), a filtration system, ten
adjustable hydrotherapy jets, and a powerful whirlpool
jet. Follow the guidelines below to use and maintain
the spa for your long-term enjoyment.

PLUGGING IN THE HYDROTHERAPY SPA

Important: The hydrotherapy spa is equipped with a
120/240V convertible electronics package. Operation
at 240V will allow the heater to run more efficiently
and less often. Conversion of the spa to 240V oper-
ation must be performed only by a qualified,
licensed electrician and must comply with all
local, state, and federal electrical codes. 
Please
refer to the instructions on the inside of the electronics
package for information about converting the spa to
240V operation.

Once the hydrotherapy spa is filled with water, the
power cord can be plugged in and the spa can be
turned on. Note: The first time the power cord is
plugged in, the spa will turn on automatically.

When connecting the power cord, plug the power cord
directly into a grounded circuit capable of carrying 15
or more amps. No other appliance should be on the
same circuit. Replace the power cord immediately if it
becomes damaged.

The power
cord is
equipped
with a
Ground
Fault Circuit
Interrupter
(GFCI). You
should
always test
the GFCI
before using
the hydro-
therapy spa. First, turn on the spa by pressing the jet
button on the console (see USING THE CONTROLS
on page 12). Once the spa is running, press the GFCI
“test” button. The spa should shut off. Press the
“reset” button. The spa should resume normal opera-
tion. If the spa continues to run after the “test” button
is pressed, the GFCI is damaged. Do not use the spa
until the GFCI has been repaired or replaced by a
qualified electrician.

TESTING AND TREATING THE WATER

The hydrotherapy spa comes with a starter chemical
pack for maintaining the water in the spa. Disregard
the directions on the individual packages of “QUICK
pHix It DOWN” and “QUICK pHix It UP.” However, the
directions on the bottle of “Non-chlorine Shox” and
“Bromine Base” are correct. Always keep the chemi-
cals away from children and pets.

The first time you use the spa, you should test and
treat the water. You must also treat the water each
time you refill the spa. 
Once you have verified that
the spa is functioning properly, and have allowed the
water to circulate for a while, you should remove the
spa cover and add 1/3 of the “Bromine Base” bottle,
and 1/3 of the “Non-chlorine Shox” bottle to the water
in the spa. Allow the water to circulate for five min-
utes. You should now test the pH level of the water by
using the included test strips. Refer to the test strip
packaging for instructions on using the test strips. The
pH reading should be between 7.2 and 7.8. 

If the level is too low, add half of one of the “QUICK
pHix It UP” packets to the water. Let the water circu-
late through the spa for five minutes. Test the pH level
again. Repeat until the pH level is correct.

If the level is too high, add half of one of the “QUICK
pHix It DOWN” packets to the water. Let the water cir-
culate through the spa for five minutes. Test the pH
level again. Repeat until the pH level is correct.

See WATER CHEMISTRY on page 14 for information
concerning proper water maintenance.

STARTING THE HYDROTHERAPY SPA

Once you have tested the GFCI, you should verify the
water flow from the pumping unit. Set the air control
on the console to the lowest setting (see USING THE
CONTROLS on page 12). The pumping unit will heat
the water as it pumps. Cover the hydrotherapy spa
with the spa cover. The spa cover must be tight
(see SECURING THE SPA COVER ON THE SPA on
page 11). The water will heat at about 1.8°F per hour
with the cover on. If you are using the spa indoors,
and the room temperature is maintained at 70°F, it will
take approximately 24 to 36 hours for the water to
reach the set temperature.

The temperature and the water flow can be set or
changed with the controls on the console (see USING
THE CONTROLS on page 12).

Test and

Reset

Buttons

Grounded

circuit capable

of carrying 15

or more amps

GFCI

Using the Hydrotherapy Spa

Summary of Contents for IMHS45592

Page 1: ...s on our customer hot line will provide immediate assis tance free of charge to you CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 6 a m 6 p m MST Model No IMHS45592 Serial No The serial number is found on...

Page 2: ...6 Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all user...

Page 3: ...se high temperatures can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not brin...

Page 4: ...a cover when the spa is not in use 29 WARNING To reduce the risk of injury The water temperature should never exceed 104 F Temperatures between 100 F and 104 F are considered to be safe for healthy ad...

Page 5: ...e included warning sign must be posted where all users of the hydrotherapy spa can see and read it See POSTING THE WARNING SIGN on page 2 40 The causes symptoms and effects of hyper thermia may be des...

Page 6: ...l your best For your benefit read this manual carefully before using the RENEW 455 If you have additional ques tions please call our Customer Service Department toll free at 1 877 897 7493 Monday thro...

Page 7: ...he spa provided you leave access to the motor for ser vice 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the hydrot...

Page 8: ...you begin Tighten all parts as you assemble them unless instructed to do otherwise ASSEMBLY REQUIRES THE FOLLOWING TOOLS not included One 1 phillips screwdriver You may also need a small amount of so...

Page 9: ...atable Cover Slide one of the straps on the inside of the Spa Cover 11 through one of the loops on the Inflatable Cover 4 Attach the latch on the strap to the buckle on the other end of the strap Make...

Page 10: ...ges of QUICK pHix It DOWN and QUICK pHix It UP However the directions on the bottle of Non chlorine Shox and Bromine Base are correct Always keep the chemi cals away from children and pets The first t...

Page 11: ...ver operate the spa without the suction covers in place G The air control determines the amount of air flowing through the spa jets during operation see USING THE CONTROLS on page 12 H The filter can...

Page 12: ...plugged in or if the buttons on the console have not been pressed for longer than twenty minutes the automatic mode will begin filtering or heating the water as needed Note To keep the filter and heat...

Page 13: ...ver should be cleaned monthly To clean the spa cover use water and a non abrasive cleaner on the entire cover Rinse the cover with a garden hose to remove any cleaner residue Dry the cover entirely Us...

Page 14: ...st strips or purchase a pH test kit at a pool and spa supply store The pH read ing should be between 7 2 and 7 8 If the level is too low add a pH increaser usually soda ash If the level is too high ad...

Page 15: ...the spa 1 Drain the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 2 Remove all remaining water from the spa shell Dry the spa shell with towels 3 Set the air control to the...

Page 16: ...t temper ature b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See the chart below for the approximate heating time Air Temperature Heating Time 70 F 13 to 18...

Page 17: ...ydrotherapy jets can be closed and opened by pushing and pulling the nozzles If no air flows through the hydrotherapy jets when the air control is turned counterclock wise simply pull the nozzles slig...

Page 18: ...rews 16 1 Filter 17 2 10 x 1 1 4 Screw 18 2 Suction Cover 19 1 Locking Ring 20 1 Pump Motor 21 1 Pump Motor Power Cord 22 1 Strain Relief 23 1 Light Cover 24 4 5 16 Lock Washer 25 1 Diverter Knob 26 3...

Page 19: ...19 23 18 17 11 5 4 22 35 25 33 19 15 8 16 7 2 7 9 10 26 18 31 30 34 3 10 33 32 29 26 10 24 5 12 21 14 6 13 28 27 20 6 12 36 1 Exploded Drawing Model No IMHS45592 R1200A...

Page 20: ...llowing incidents any damage to the surround or frame attributable to improper handling or freight damage damage resulting from improper win terization damage to the spa shell resulting from improper...

Reviews: