background image

9

5. After a qualified electrician has wired the spa to a

240 volt power source, refer to the inset drawing.
Set the Filter (16) into the filter housing. Next, screw
the Filter Cover (8) into the filter housing until it is
fully seated.

Remove the two warning decals (not shown) from
the spa shell. Using a damp cloth, wipe the spa shell
clean. Before filling the spa, make sure that it is
in the desired position and that there is room to
easily service the spa. Once the spa is filled, it
will have to be drained before it can be moved.

Using a garden hose or other clean water source,
begin filling spa. Do not use soft water. The spa
may be filled with cold water; however, if warm or
hot water is used, the spa will be ready for use
sooner. Fill the spa until the water is at the level
shown at the right. Do not overfill the spa.

3. Refer to the drawing on page 6 and locate the

heater access opening.

Locate the two indicated gate valves inside the
heater access opening. Make sure that the gate
valves are open and that the locking clips are
snapped onto the stems of the gate valves (refer to
the inset drawing in step 2 on page 8).

Make sure that the four indicated collars are tight-
ened.

Refer to step 1. Re-attach the heater Access Panel
(5) to the spa with the four 1/4” x 1 1/2” Machine
Screws (7).

4. The hydrotherapy spa operates on a 240 volt power source and must be wired directly to a 240 volt ground

fault circuit interrupter (GFCI) installed in your home. This procedure must be performed by a qualified
electrician. A wiring diagram is found on the inside of the electronics pack as a reference. Under no
circumstances should the spa be wired by someone other than a qualified electrician. 
Before you
have the spa wired, make sure that it is in the position you want, and that it can be easily serviced, if needed.

6. Pull down one of the straps on the Spa Cover (11)

and hold the Buckle (30) against one of the
WeatherWood™ panels on the spa. (Note: To posi-
tion the Buckle correctly, have a second person hold
the strap on the opposite side of the Spa Cover
tight.) The Spa Cover must be tight. Do not place
the Buckle over the grooves between the
WeatherWood™ panels. 
Refer to the inset drawing.
Remove the latch from the Buckle (30). Attach the
Buckle to the WeatherWood™ panel with two #4 x
3/4” Screws (31).

Attach the other five Buckles (30) to the
WeatherWood™ panels in the same way.

Remove the Spa Cover (11) from the spa.

5

3

Fill to Here

Filter

Housing

Collar

Collar

Collar

Gate

Valve

Electronics Pack

Gate

Valve

6

11

30

Strap

Strap

Latch

30

31

8

16

Filter

Housing

Summary of Contents for IMHS63100

Page 1: ...techni cians on our customer hot line will provide immediate assis tance free of charge to you CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 6 a m 6 p m MST Model No IMHS63100 Serial No The serial number is on a plastic sign inside the spa behind the access panel Record the serial number in the space above CAUTION Read all precautions and instruc tions in this manual before using this equipment Save th...

Page 2: ...16 Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all users of the hydrotherapy spa Whenever the spa is moved the sign must also be moved and reposted near the spa If the sign becomes lost or illegible call our toll free Customer Hot Line at 1 877 897 7493 ...

Page 3: ...es can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into the hydrotherapy spa that could damage the spa shell 10 Never insert any object into any opening 11 Do not use breakable containers in or near the hydrotherapy spa 12 Do not sit on the spa cover or pl...

Page 4: ...injury Pregnant women should consult with their physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be seriously harmed This is especially important during the first 90 days of the pregnancy 29 DANGER To reduce the risk of drowning Prolonged immersion in the hydrotherapy spa may cause hyperthermia The caus...

Page 5: ...RNING The spa jets produce a stream of water with relatively high pressure Prolonged exposure of a localized area of the body may cause bruises to the skin 36 The included warning sign must be posted where all users of the hydrotherapy spa can see and read it See POSTING THE WARNING SIGN on page 2 37 WARNING DECAL PLACEMENT Locate the decals shown below and familiarize yourself with the informatio...

Page 6: ...l your best For your benefit read this manual carefully before using the RENEW 631 If you have additional ques tions please call our Customer Service Department toll free at 1 877 897 7493 Monday through Friday 6 a m until 6 p m Mountain Time excluding holidays To help us assist you please mention the product model number and serial number when calling The model number is IMHS63100 The serial numb...

Page 7: ...f the spa provided you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa If you set up the hydrotherapy spa outside 1 Check local building codes concerning the use of outdoor spas 2 The spa should be located near a power source capable of suppling 240 volts AC power It mus...

Page 8: ...in Tighten all parts as you assemble them unless instructed to do otherwise ASSEMBLY REQUIRES THE FOLLOWING TOOLS not included One 1 phillips screwdriver You may also need a small amount of soap or water A wire connector is provided on the electronics pack of the spa to connect a minimum No 8 AWG 8 04 mm2 solid copper conductor between the spa and any metal equipment electrical enclosure made of m...

Page 9: ...ght ened Refer to step 1 Re attach the heater Access Panel 5 to the spa with the four 1 4 x 1 1 2 Machine Screws 7 4 The hydrotherapy spa operates on a 240 volt power source and must be wired directly to a 240 volt ground fault circuit interrupter GFCI installed in your home This procedure must be performed by a qualified electrician A wiring diagram is found on the inside of the electronics pack ...

Page 10: ...d be between 7 2 and 7 8 If the level is too low add half of one of the QUICK pHix It UP packets to the water Let the water circu late through the spa for five minutes Test the pH level again Repeat until the pH level is correct If the level is too high add half of one of the QUICK pHix It DOWN packets to the water Let the water cir culate through the spa for five minutes Test the pH level again R...

Page 11: ...ven port jet returns heated water into the spa and provides a soothing foot massage I The temperature probe monitors water tempera ture J The underwater light can be used for night opera tion see USING THE CONTROLS on page 12 K The three suction vents near the floor of the spa bring water into the pumps in order to operate the system Never operate the spa without the suc tion covers in place L The...

Page 12: ...at heats and filters the water when the spa is left unattended When the power to the spa is first turned on or if the buttons on the console have not been pressed for longer than twenty minutes the automatic mode will be activated The automatic mode will filter the water for one hour every six hours The water will be heated as required to maintain the set temperature and returned to the spa throug...

Page 13: ...n do not use solvents The spa should always be clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover use water and a non abrasive cleaner on the entire cover Rinse the cover with a garden hose to remove any cleaner residue Dry the cover entirely Use a non silicone based vinyl conditioner on the cover after you clean it T...

Page 14: ...ither purchase additional test strips or purchase a pH test kit at a pool and spa supply store The pH read ing should be between 7 2 and 7 8 If the level is too low add a pH increaser usually soda ash If the level is too high add a pH reducer usually sodium bisulfate Test the water again after five minutes See the instructions with your pH test kit for additional information about testing and adju...

Page 15: ...sure the power to the spa is turned off 2 Drain the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 3 Remove all remaining water from the spa shell Dry the spa shell with towels 4 Set the air control to the lowest setting Use a wet dry vacuum to pull any remaining water from the system To do this place the vacuum nozzle over each jet starting with the highest jet and fin ...

Page 16: ...et tempera ture b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See the chart below for the approximate heating time Air Temperature Heating Time 70 F 6 to 8 hours 50 F 70 F 9 to 11 hours 30 F 50 F 12 to 14 hours b If the water still has not heated after four days contact our customer service department 7 SYMPTOM THE WATER IS NOT BEING CLEANED BY THE FILTE...

Page 17: ...ol is turned counterclockwise simply pull the nozzles slightly 12 SYMPTOM THE CONSOLE DISPLAYS THE WORDS COOL OR ICE a This is a normal function of the spa no action is necessary The word COOL will appear in the display if the temperature of the water is more than 20 F cooler than the set tempera ture If this happens the heater will automati cally activate to warm the water The word ICE will appea...

Page 18: ...ater Pump Motor Power Cord 20 2 Jet Pump Motor 21 2 Jet Pump Motor Power Cord 22 2 Strain Relief 23 1 Heater Pump Motor Grommet 24 11 5 16 Lock Washer 25 4 Corner Panel 26 8 Adjustable Push Pull Jet 27 2 Drain Plug 28 2 Drain Plug O ring 29 1 Small Quick release Bracket 30 8 Buckle 31 16 4 x 3 4 Screw 32 13 Whirly Jet 33 1 Filter Cover O ring 34 2 Air Control Knob 35 11 1 4 x 1 1 4 Bolt 36 2 Large...

Page 19: ...8 37 1 26 30 31 14 27 28 13 20 22 35 36 11 7 2 7 5 25 25 25 16 24 35 6 32 26 26 10 17 18 17 12 9 9 33 38 38 38 3 23 24 38 13 27 28 13 20 22 35 24 38 13 38 24 36 24 35 38 38 24 21 32 32 39 40 40 Exploded Drawing Model No IMHS63100 R0700A ...

Page 20: ...es caused by or attributable to the following incidents any damage to the WeatherWood sur round or steel frame attributable to improper handling or freight damage damage resulting from improper win terization damage to the spa shell resulting from improper chemical treatment damage to the spa shell result ing from exposure to extreme temperatures or damage to the spa shell resulting from exposure ...

Reviews: