background image

18

Part List

—Model No. IMSB73911/IMSG73911

R0302A

1

1

Thermometer Fitting

2

1

3-wire Power Cord

3

2

Filter Cover with O-Ring

4

2

Filter O-Ring

5

2

Filter

6

2

Rubber Isolator

7

1

Blue Light Cover

8

1

Red Light Cover

9

12

#10 x 1” Sheet Metal Screw

10

1

2-speed Pump

11

1

Spa Cover

12

9

Dual Rotary Jet Face

13

4

Jet Pump/Motor O-ring

14

1

Heater/Electronics Package*

15

3

Medium Jet Housing

16

4

#10 x 1 1/4” Screw

17

4

Suction Cover

18

4

Air Control Knob

19

1

1-speed Pump

20

2

4-wire Power Cord

21

1

Diverter

22

1

Basket

23

8

1/4” Lock Washer

24

1

Filter Door

25

4

Access Panel

26

4

Buckle

27

8

#4 x 3/4” Screw

28

10

#8 1 1/2” Screw

29

1

Console with Overlay

30

1

Hose Washer

31

8

1/4” Washer

32

1

Diverter Valve

33

1

Trim Plate

34

1

Foam, Weir

35

1

Volcano Jet

36

3

Nozzle Housing

37

21

Small Rotator

38

1

Large Rotary Jet

39

1

Face Ring

40

1

Small Nozzle

41

22

Jet Ring

42

1

Nozzle Bushing

43

21

Pivot Ring

44

3

Medium Nozzle

45

2

Drain Plugs

46

32

#10 x 2” Sheet Metal Screw

47

1

Pillow

48

2

Drain Plug O-ring

49

4

Corner Panel

50

1

Hose Cap

51

1

Skimmer Housing*

52

9

Dual Rotary Jet

53

2

Neck Jet

54

1

Whirlpool Jet

55

1

Overlay

#

2

Ground Wire

#

2

Key

#

1

User’s Manual

#

1

Large Warning Sign

#

1

Warning Sign

#

1

Light Bulb

#

4

Corner Panel 

* Indicates a part that is serviceable only by service

technicians.

# Indicates a non-illustrated part.

Specifications are subject to change without notice.

Key No. Qty.

Description

Key No. Qty.

Description

51

7

8

50

30

24

34

33

32

21

22

28

Summary of Contents for IMSB73911

Page 1: ...l provide immediate assistance free of charge CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 8 a m 5 p m CST Model No IMSB73911 IMSG73911 Serial No The serial number is on a sign behind the access panel Wri...

Page 2: ...Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all users...

Page 3: ...s can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into t...

Page 4: ...njury Pregnant women should consult with their physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be serio...

Page 5: ...NING The spa jets produce a stream of water with relatively high pressure Prolonged exposure of a localized area of the body may cause bruises to the skin 36 The included warning sign must be posted w...

Page 6: ...best For your benefit read this manual carefully before using the IMAGE RENEW 739 If you have ques tions after reading the manual please call our Customer Service Department toll free at 1 877 897 74...

Page 7: ...the spa provided you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa I...

Page 8: ...During assembly make sure that all parts are oriented as shown in the drawings Read each assembly step before you begin Tighten all parts as you assemble them unless instructed to do otherwise ASSEMB...

Page 9: ...lt power source and must be wired directly to a 40 amp Ground Fault Circuit Interrupter GFCI protected circuit breaker installed in your home This must be performed by a qualified licensed electrician...

Page 10: ...maintenance STARTING THE HYDROTHERAPY SPA You should always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the pump button 1 on the console see USING THE CONTROLS on...

Page 11: ...led to utilize the ozone jet Ozone helps sani tize the spa with minimal chemical treatment H The console controls the spa jets turns the under water light on and off and adjusts the water tem perature...

Page 12: ...when the spa is left unattended When the power to the spa is first turned on or if the water temperature is below the set temperature the water will be heated as required Note To keep the filter and...

Page 13: ...clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover use water and a non abrasive cleaner on the entire cover Rinse the...

Page 14: ...ontact your local pool and spa supplier for information concerning which chemicals you should use in your area to sanitize the spa CHANGING THE FILTER CYCLE The spa will filter the water every 12 hour...

Page 15: ...the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 3 Remove all remaining water from the spa shell Dry the spa shell with towels 4 Set the air controls to the lowest setting...

Page 16: ...the air control to low The water will heat at a rate of 6 F per hour If you are using the spa indoors and the room temperature is main tained at 70 F it will take approximately 6 to 8 hours for the w...

Page 17: ...ce the damaged seal b Some water loss due to evaporation is normal If rapid water loss occurs or if you notice wet ness on the floor around the hydrotherapy spa the spa shell may have a leak Contact y...

Page 18: ...9 1 Console with Overlay 30 1 Hose Washer 31 8 1 4 Washer 32 1 Diverter Valve 33 1 Trim Plate 34 1 Foam Weir 35 1 Volcano Jet 36 3 Nozzle Housing 37 21 Small Rotator 38 1 Large Rotary Jet 39 1 Face Ri...

Page 19: ...10 9 23 31 13 13 19 9 23 31 13 20 1 12 2 15 37 43 44 36 40 39 41 42 41 38 35 46 46 16 17 16 17 16 17 16 17 46 46 25 6 6 9 5 3 4 5 3 4 47 45 48 45 48 14 9 9 54 52 53 53 49 55 Exploded Drawing Model No...

Page 20: ...to the following incidents any damage to the premium cedar surround or frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell r...

Reviews: