- Grooming - Mapping
Figure 60.
Create GigE Input TS
Selecting
No SSM
Redundancy
Selecting
SSM
Redundancy
1.
At the
Create GigE Input Transport Stream
dialog, enter information about the transport stream.
2.
Click
OK
to apply the configuration and to dismiss the dialog. The new TS will now be displayed in
the
Inputs panel
for the specified port.
Table 60.
Create GigE Input Transport Stream Parameters
Input Transport Stream
Description
GigE Port
This is the read-only port ID, and is based on the selected GigE port (GigE 1,
GigE 2, etc.)
TS Name
Alphanumeric string to name the transport stream. This name will be displayed
on the mapping page.
Multicast
If this is a multicast stream, check this box to enable multicast.
SSM Redundancy
Check to enable Source Specific Multicast (SSM) mode. If checked, you can
configure up to four source IP addresses.
SSM Redundancy
can only be checked if
Multicast
is also checked.
IP Address
The unicast or multicast IP address on which the stream is received.
UDP Port
Enter the UDP port to use for transmitting data.
Source IP Address [1-4]
The IP address of the source from which the stream is originating.
The
Source IP Address
can only be configured if
Multicast
is checked.
If
SSM Redundancy
is unchecked,
Source IP Address 1
is available and
optional and should only be included for IGMPv3/SSM transport streams.
If
SSM Redundancy
is checked,
Source IP Address 2
to
4
are available. At least
two source IP addresses must be configured. All source IP addresses must be
unique.
Multiple TS
Click this button if you are creating multiple transport streams. You can create
incrementing IP addresses, incrementing UDP ports, or incrementing IP
Addresses and UDP ports simultaneously. See also “Multiple IP and UDP
Creation” on page 111/