BNP User Guide, Release 3.7.1
187
- Software Upgrade
Figure 136. Upgrade Software dialog
Provide information in all fields.
Table 86.
Standalone Chassis Software Upgrade Steps
Step
Description
1.
Upgrade the BNP
chassis.
At the
Upgrade Software
screen:
a.
Type the FTP Host, User Name, Password, and Directory and File
Name:
Un-check
the
Reboot chassis after successful software
upgrade
option.
b.
Click
Upgrade
and wait until you see the 100% completion message in
the Upgrade Log.
2.
Shut down the chassis.
Log into the BNP via its
Physical IP
address and use the
Maintenance ->
menu to perform a .
3.
Remove power from
the chassis.
After shutting down the system through the
Element Manager
, wait
one minute (or until the Fault LED has stopped blinking) and unplug
the power cord from the chassis.
4.
Power cycle the BNP.
Apply power to the BNP and wait until the chassis is accessible
through the GUI and output streams are verified.
Table 87.
Upgrade Software - Configuration Fields
Field
Description
FTP Host
Enter the IP address of the FTP server on which the upgrade software
package resides.
User Name
Enter the user name needed to access the FTP server.
Password
Enter the password for the user name provided above.
Path
Enter the source location of the upgrade software. Specify the
directory and file name using the format shown on the
Upgrade
Software
dialog.