Selenio
TM
BNP User Guide, Release 3.7.1
143
- Grooming - Mapping
-
Table 74, “Configure Program Mapping—Grooming Parameters—ETV Configuration,” on
-
Table 75, “Configure Program Mapping—Grooming Parameters—Destination,” on page 145
-
Table 76, “Configure Program Mapping—Grooming Parameters—Grooming Schedule,” on
-
Table 77, “Configure Program Mapping—Grooming Parameters—Quality of Service,” on
-
Table 78, “Configure Program Mapping—Grooming Parameters—Component PIDs,” on
-
Table 79, “Quality of Service Levels,” on page 147.
If this is a backup program, click the
Program Redundancy
tab and enter the input ports,
transport streams, and programs. (See “Program Redundancy” on page 152 for details.)
3.
Click
OK
to save and use the settings.
Table 73.
Configure Program Mapping—Grooming Parameters—Source
Field
Description
Port
Read-only. Specifies the input GigE or ASI port used for the input program. The GigE
port to use, transport stream ID, program name and number for both the source and
the destination of this program must be defined. For input streams, you can choose to
Forward SCTE 35 Cue. For output streams, you can enable and specify PMT PID, and
enable SCTE 30 to 35 Conversion.
TS ID
Read-only. Specifies the input Transport Stream ID used for the input program.
Program Number
Read-only. Specifies the program number for the input program.
Program Name
Read-only. Specifies the program name (if one was given) for the input program.This
section also displays pass-through status as either enabled (checked) or disabled (un-
checked) for long and short program names.
Synchronize input
and output program
names
Check this box to copy the input program name into the output program name at
creation time.
An output program can have up to three names when it is part of an ATSC transport
stream, to serve the following purposes:
• The unique name, which is used for DPI purposes, that enables the BNP to identify
the program.
• The short name (max 7 characters), for use in ATSC tables. The short name is not
required to be unique at the BNP or at the output TS level.
• The long name (max 32 characters), for use in ATSC tables. The long name is not
required to unique at the BNP or at the output TS level.
Short Name
If available, string consisting of 1 - 7 characters, which identifies the short program
name.
Long Name
If available, string consisting of 1 - 32 characters, which identifies the long program
name.
Forward SCTE 35
Cue
Check this box to forward SCTE 35 cue tones from the input program.
You cannot select this option and SCTE 30 to 35 Conversion for the same output
program.