BNP User Guide, Release 3.7.1
198
- Removing Chassis Redundancy
Removing Chassis Redundancy
Use the
Remove Chassis Redundancy
function to tear down the redundant configuration between a
pair of BNPs.
Menu Path
Element Manager
main menu -->
Maintenance
(Alt
m
)-->
Remove Chassis
Redundancy
(Alt
r
)
The
BNP Element Manager
will query for confirmation of
the removal.
At the
Confirmation
dialog, click
Yes
to proceed, or
No
to dismiss this dialog.
Regrooming
Regrooming lets you reset all of the programs that are currently configured in Program Redundancy to
their Active Programs. Once initiated, the command will check to see that the active program has been
restored. If the active program has not been not restored, no change will occur to the current state of
the program.
The Regrooming feature resets all programs with a properly detected primary program available.
Note:
This feature cannot be used to regroom a selected stream.
To Reset all of Grooming to the Active Chassis
Use the
Regroom
function to apply a chassis regroom on the active BNP.
Menu Path
Element Manager
main menu -->
Maintenance
(Alt
m
)-
-> Regroom
(Alt
g
)