VMG-14+ Chassis and Components
Gen2 Release 1.4.0
Shelf
Control
Managers
The VMG-14+ SCMs fit into the dedicated SCM slots located at the left-front-edge of the chassis. Two
SCMs are required for redundancy, and an SCM in either slot can serve as the primary. When the active
is removed, the remaining SCM changes state—from standby to active.
Note:
Although each Shelf Manager module contains a mini DB25 Telco Alarm interface at the RS-232
port, telco alarm LEds, and Telco alarm cutoff push button, the current release does not support
Telco alarm functionality.
The SCM faceplate provides the LEDs and components illustrated in
.
Figure 8.
Shelf Control Manager Front Panel
Filler Panels
• Front Filler
• RTM Filler Panels
See also
all empty slots
Fan Tray
See also
2
Fan Tray slot, below
cable management
tray.
Fan Filter Tray
See also
1
Front of chassis,
above fan trays, and
below cable
management tray.
Table 3.
VMG-14+ Chassis Modules and Components (Continued)
Name
Description
System
Capacity
Slot Assignments
Table 4.
Shelf Control Manager—Front Panel
LED Name
Color/Condition
Description
Cutoff Button
n/a
Not supported for the current release.
Reset Button (RST)
n/a
Reset (power cycle) the SCM. Use a small pointed
object to access and depress this button.
Fault LEDs
Green
Temperature normal: not exceeding thresholds. This
LED illuminates upon system power-up.
Red Temperature
exceeds
thresholds.
Ethernet Link
Activity Status
RJ-45 Port
Reset
RS-232 Port
(not used)
Hot Swap
LED
SCM Status LED
Alarm
Cutoff
Fault
LEDs
Extraction
Lever
Fixing
Screw
Fixing