Selenio
TM
VMG-14+ Hardware Setup Guide
29
VMG-14+ System Modules
Gen2 Release 1.4.0
Application
Media
Processor
The AMP (
) provides the interface, indicators and functions described in the following
sections:
•
.
•
Figure 16.
AMP Module Front Panel.
For AMP usage in the VMG-14+, one AMP module is always paired with an NPM, using the following
rules:
•
The AMP in slot 3 must be paired with the NPM in slot 1.
•
The AMP in slot 4 must be paired with the NPM in slot 2.
Note:
If you are using AMP Cards, you must install the same number of AMP cards as NPM cards. A
configuration such as two NPMs and one AMP, or one NPM and two AMPs is not supported.
Note:
If you are not using AMP Cards, you do not need AMP modules and can install TCM and VPM
modules in slots 3 and 4 instead. If you previously used AMP modules and are now using TCM
and/or VPM modules in those slots instead, you must power cycle the VMG in order for those
modules to come up.
AMP
Interfaces
The AMP module interfaces with an NPM via direct connectivity between the ETH ports of the AMP to
the SFP GigE ports on the NPM. Each AMP must be paired to an NPM, using guidelines provided in
“AMP-to-NPM Cabling” on page 49
AMP
LEDs
describes the AMP front panel LEDs.
Table 13.
AMP Front Panel LEDs
LED Name
Color/Condition
Description
OOS (Out of
Service)
Red
System out of service.
Off
System normal.
Health
Solid green
AMP firmware is active, payload enabled.
Flashing green
AMP firmware is active, payload disabled.
Off
AMP firmware is inactive.
ETH 1
ETH 2
USB ports
OOS
Health
Hot Swap
Serial 1
Reset