10
Installation Troubleshooting
•
During installation, first test the fiber and twisted pair connections with all
troubleshooting features disabled, then enable these features, if desired, just
before final installation. This will reduce the features’ interference with testing.
•
When connecting to an end device, such as another switch, be sure to use the
same configuration on its port as well as the IE-iMcV-MediaLinX TX/SFP. For
example, if the end device is set to a FORCE mode, then set the copper port of
the IE-iMcV-MediaLinX TX/SFP to a FORCE mode as well.
If using a high powered device (which is designed for long distance installations) for a
short distance installation, the fiber transmitters may overdrive the receivers and
cause data loss. If this is the case, an optical attenuator may need to be added to the
connection.
For fiber specifications, visit the IMC Networks Web site at:
www.imcnetworks.com/adocs/fcs.asp
or contact IMC Networks for more information.
Specifications
Environmental
Operating Temperature
IE: -40°F to +185°F (-40°C to +85°C)
Non-IE: +32°F to +122°F (0°C to +50°C)
Storage Temperature
-13°F to +158°F (-25°C to +70°C)
Humidity:
5 - 95% (non-condensing)
Power Consumption (Typical)
300mA
Fiber Optic Specifications
For fiber optic specifications, please visit:
http://www.imcnetworks.com/adocs/fcs.asp
IMC Networks Technical Support
Tel:
(949) 465-3000 or (800) 624-1070 (in the U.S. and Canada);
+32-16-550880
(Europe)
Fax:
(949) 465-3020
E-Mail:
techsupport@imcnetworks.com
Web:
www.imcnetworks.com