4
FROSTAR FR60 and FR90
INSTALLATION
For the Installer
:
These Instructions contain important information designed to help the user obtain
the maximum benefit from the investment in a Frostar unit.
Please read them carefully before starting work, and consult with the supplier in the
event of any queries.
Be sure to leave this Instruction Manual with the user after the installation of the
units is complete.
Procedure:
Install the unit on a flat and level floor, allowing space for ventilation at the front,
back and sides.
Do not install the unit close to a heat source such as a radiator or the warm air
outlet of another piece of refrigeration equipment.
If supplied, fit the bottle opener(s) and catcher(s) to the front of the unit.
If the cabinet has been stored on its front, back, or sides during transit, stand the
cabinet upright for a minimum of two hours before starting. This will avoid damage
to the compressor.
PREPARATION
The electrical supply to the unit should be 220/240 Volt, 1 phase, 50 Hz.
All units are supplied with a standard mains plug fitted with a 10 Amp fuse. This
should be plugged into a standard mains socket. The unit must be positioned so
that the plug is accessible.
Warning - This machine must be earthed
If the supply cord is damaged, the manufacturer, an approved service engineer or
a qualified electrician in order to avoid a hazard, must replace it.
If a new mains supply is to be run to the machine, the work must be always
undertaken by a reputable and competent electrician, and the IEE Codes of
Practice must be observed.
Site conditions may vary with additional lengths of cable runs, encapsulation in
trunking, bunched with other cables etc, needed. Should this apply, the electrician
must alter the cable accordingly.
It is imperative that all electrical work must be carried out by a qualified electrician
and in accordance with the current local regulations.