1.12.5 Transport of the
DINO-CONDENS-
IT
The system must not be tilted during transport.
If the
DINO-CONDENS-
IT
will be transported over greater distances,
and it filled with Galden
, it should be
secured on a pallet or similar platform to prevent slipping or tripping over and losing the expensive Galden.
Caution: May be transported only in the cold state!
1.13
Inspection, Unpacking, Installation & Commissioning
1.13.1 Unpacking and inspection for transport damage.
Please check the system on delivery for transport damage.
For Visible transport damage, immediately inform your carrier and
make a note on the delivery note of your
carrier.
Later,
hidden transport damages must immediately put in writing to the freight forwarder and us.
Contents of the Carton
Inside the carton you should find the following items:
Table 1: Contents of Carton for each
DINO-CONDENS-
IT
Item
FLEX
"
DINO-CONDENS-
IT
,-"
1 no.
Lid/Cover with glass window
1 no.
This owner`s manual
1 no.
AC Power cable
1 no.
Dipstick to measure the Galden Level in the process chamber
1 no.
Pump = 100 ml large hypodermic syringe for emptying
1 no.
Initial filling GALDEN
(minimum quantity ca. 1648 ml 1.65
Liter)= 3 Kg GALDEN
1648 ml
.
Gloves
1 set.
(Other items may be included that are not listed above. See the packing list in the carton for all the items in the
carton).
1.13.2 Installation and commissioning
The
DINO-CONDENS-
IT
should be stored in place and operated where no excessive or condensing humidity is
present and the ambient temperature should never be below freezing point.
As the unit is air cooled, a higher ambient temperature will lead to a reduced cooling capacity and thus extend the
cooling time.
The
DINO-CONDENS-
IT
must have a free space of at least 30 cm on both sides (ventilation slits side) to aid
sufficient air circulation.
Be warned that at the left and right side of the device are ventilation slits, where for a short time (immediately at
the end of a solder process) up to
140 °C 284 °F
warm air can be blown out!
The device should be operated only on horizontal surfaces which are firm and non-slippery.