In which mode I want my product?
Periodical
Peri
Alarm
Alarm with
thresholds
What is my sampling period?
A sample every X
seconds
A sample every X
seconds
A sample every X
seconds
I divide by 2 this value
and indicate it in the
register S321
I divide by 2 this value
and indicate it in the
register S321
I divide by 2 this value
and indicate it in the
register S321
I want to save each
sample
I indicate 1 in the regis-
ter S320
When the frame will be sent ?
I want to read
regularly in case of a
threshold is overpassed
but I want to save the
information only each Y
samples
When do I want to save the information?
I indicate this Y value in
the register S320
In alarm mode I do
not need to save the
information
No need to indicate a
value in the register
S320
I want to optimize the
frame in order to send
the minimum of frame
per day
I indicate the number of
samples I want in the
frame in the register
S301 (in Sigfox RC1
5 being the max for 1
probe activated and 2
for 2 probes activated)
I want to optimize the
frame in order to send
the minimum of frame
per day
I indicate the number of
samples I want in the
frame in the register
S301 (in Sigfox RC1
5 being the max for 1
probe activated and 2
for 2 probes activated)
The frame is sent
when a threshold is
overpassed
I indicate 0 in the reg-
ister S301 to deactivate
the periodical transmis-
sion
I configure the
thresholds in registers
S330 to S334
and S340 to S344
I configure the
thresholds in registers
S330 to S334
and S340 to S344