CONTO D6 

Three-phase energy meter

Installation manual

 • 

Installationsanweisungen

• List of abbreviations

CodE

Password

tIME

Power integration time

Addr

Address

bAUd

Communication speed in kbps

PAr

Parity

nonE

No parity

EVEn

Even parity

odd

Odd parity

tIM

Delay response (ms)

PLSt

Pulse output setting

ACt

Active energy (kWh)

rEA

Reactive energy (kvarh)

PLSU

Pulse value

PLSd

Pulse duration

thr

Starting the time counter associated with the power

PSU

Password customisation

SAUing

Saving settings

k

kilo (eg.: kVA = kilo Voltamps)

M

Mega (eg.: MVA = Mega Voltamps) 

T

Total energy value

P

Parzial energy value

PMD

Average power demand

MD

Average power

h

Hour counter (Hours and Minutes)

Ux.yyy

Firmware version

Energy counting - Tariff 1

Energy counting - Tariff 2

PF

Power factor

Fr

Frequency

Itr

Transitional current

Iref

Reference current (10Itr)

• Liste der Abkürzungen

CodE

Zugriffscode

tIME

Integrationszeit Leistungen

Addr

Adresse

bAUd

Kommunikationsgeschwindigkeit in kbps

PAr

Parität

nonE

Parität keine

EVEn

Parität Gleich

odd

Parität Ungerade

tIM

Antwortverzögerung (ms)

PLSt

Einstellung Impulsausgang

ACt

Wirkenergie (kWh)

rEA

Blindenergie (kvarh)

PLSU

Impulsgewicht

PLSd

Impulsdauer

thr

Starten des mit der Leistung verbundenen Zeitzählers

PSU

Kennwort nach Wunsch

SAUing

Einstellungen speichern

k

kilo (Bsp.: kVA = kilo Volt Ampére)

M

Mega (z.B.: MVA = Mega Volt Ampére)

T

Gesamtwert der Energie

P

Partieller Energiewert

PMD

Leistungsspitze

MD

Leistungsmittelwert

h

Stundenzähler (Stunden und Minuten)

Ux.yyy

Firmware-Version

Energiezählung - Tarif 1

Energiezählung - Tarif  2

PF

Leistungsfaktor

Fr

Frequenz

Itr

Übergangsstrom

Iref

Bezugsstrom (10Itr)

Tomek GmbH - messtechnik@tomek.at - 01/61003-0

Summary of Contents for CE6DMID52

Page 1: ...LE11068AA 07 18 03 IM CONTOD6 Three phaseenergymeter Installation manual Installationsanweisung CE6DT1252 CE6DT1256 CE6DMID52 CE6DMID56 Tomek GmbH messtechnik tomek at 01 61003 0 ...

Page 2: ...2 2 Tomek GmbH messtechnik tomek at 01 61003 0 ...

Page 3: ...e to take these precautions could cause serious injuries Risk of damaging the device Chek the following The voltage to the voltage input terminals U1 U2 U3 and N according to the values indicated in the Technical characteristics section The network frequency 50 60 Hz Gefahren und Warnungen Diese Geräte dürfen nur von Fachleuten montiert werden Die Nichtbeachtung der vorliegenden Anweisungen entbin...

Page 4: ...E6DMID56 4 Metrological LED 5 Key pad with 3 dual function keys display or configuration 6 LCD display 7 Consult the instruction manual before installation 8 Double insulation 9 Connectionon 3 phase 4 wire line 10 Anti rotation device 11 Voltage Current 12 Frequency 13 Product code 14 Double tariff 15 Outputs 16 Working temperature 17 Accuracy class 18 Year of approval 19 Certifying board 20 Certi...

Page 5: ... x 50 mm COMBI PZ2 N MAX 2 1 x 1 mm 8 mm 2 1 x 1 mm 2 1 x 1 5 mm 0 5 x 2 5mm E RS485 5 C 55 C L1 L2 L3 B EN 50470 1 3 CE6DT125 CE6DMID5 5 Wh imp LED L1 3 L2 6 L3 9 L1 1 N 11 L2 4 L3 7 Auxiliary supply derived from the voltage terminals terminals U1 U2 U3 N Hilfsversorgung abgeleitet von den Spannungsanschlüssen Klemmen U1 U2 U3 N IF4E011 SXIIP CE6DT1256 CE6DMID56 CE6DT1256 CE6DMID56 CE6DT1256 CE6D...

Page 6: ...with the connection diagram a connection error may affect proper operation or cause damage to the device Beachten Sie bei der Verdrahtung unbedingt das Anschlussschema Ungenauigkeiten in den Anschlüssen können zu Fehlbedienungen oder Schäden am Gerät führen Wiring diagram for double tariff Schaltplan für Doppeltarif 1 C SG E 1 C V 12 24 VDC max 10 mA 1 1 E 1 C 1 i i V Tar 1 0 1 Tar 2 Input connect...

Page 7: ...ter 1 minute of inactivity on the keyboard the device exits the programming mode without saving the changes Anmerkung Nach 1 Minute Inaktivität der Tastatur beendet das Gerät die Programmierphase ohne die Änderungen zu speichern Programming Programmierung Selectable values 5 8 10 15 20 30 60 minutes Anwählbare Werte 5 8 10 15 20 30 60 Minuten Integrationtime for average power calculation Example t...

Page 8: ...alues 1 255 Anwählbare Werte 1 255 x 1 confirm bestätigen E P Q S I U OK 3 SET x 1 x 2 RS485 CE6DT1256 CE6DMID56 E P Q S I U OK 3 SET E P Q S I U OK 3 SET x 1 confirm bestätigen E P Q S I U OK 3 SET k k k x 1 Communication speed Example bAUd 9 6 Kommunikationsgeschwindigkeit Beispiel bAUd 9 6 Selectable values 4 8 9 6 19 2 bit s Anwählbare Werte 4 8 9 6 19 2 bit s Tomek GmbH messtechnik tomek at 0...

Page 9: ...onfirm E P Q S I U OK 3 SET Parity bit Example PAR odd Paritätsbit Beispiel PAR odd Selectable values EVEn odd nonE Anwählbare Werte EVEn odd nonE E P Q S I U OK 3 SET E P Q S I U OK 3 SET x 1 nonE X 2 odd RS485 CE6DT1256 CE6DMID56 Tomek GmbH messtechnik tomek at 01 61003 0 ...

Page 10: ...I U OK 3 SET E P Q S I U OK 3 SET x 5 E P Q S I U OK 3 SET Selectable values 3 99 Anwählbare Werte 3 99 x 1 confirm bestätigen E P Q S I U OK 3 SET x 1 x 1 RS485 CE6DT1256 CE6DMID56 Selectable values ACt active energy rEA reactive energy Anwählbare Werte ACt Wirkenergie rEA Blindenergie Pulse output Impulsausgang x 1 E P Q S I U OK 3 SET x 1 confirm bestätigen E P Q S I U OK 3 SET Tomek GmbH messt...

Page 11: ...le values 50 100 200 300 400 500 ms Example PLSd 100 Anwählbare Werte 50 100 200 300 400 500 ms Beispiel PLSd 100 Pulse width Impulsdauer x 1 100 ms x 2 200 ms x 3 300 ms x 4 400 ms x 5 500 ms E P Q S I U OK 3 SET x 1 confirm bestätigen E P Q S I U OK 3 SET Selectable values 0 4 50 Pn Pn 3 Phase active energy referred to 400V 10A 6900W Example thr 02 40 Anwählbare Werte 0 4 50 Pn Pn Wirkenergie 3 ...

Page 12: ... new password and store it in a secur e place Important The last password saved must be used for future access Wichtig Um zu einem späteren Zeitpunkt auf das System zugreifen zu können ist das zuletzt gespeicherte Kennwort erforderlich Bitte notieren Sie sich das neue Kennwort und bewahren Sie es an einem sicheren Ort auf Saving settings Instellungen speichern Tomek GmbH messtechnik tomek at 01 61...

Page 13: ...rgie XXXXXXXX P k Wh E E E P Q S I U OK 3 SET Average active power demand tariff 1 Durchschnittswirkleistungsspitzenwert im Tarif 1 XXXX P M D k W E P Q S I U OK 3 SET Average active power demand tariff 2 Wirkleistungsspitzenwert im Durchschnitt Tarif 2 XXXX P M D k W E P Q S I U OK 3 SET Partial reactive energy Teilblindenergie XXXXXXXX P k v a r h P Q S I U OK 3 SET Average power Leistungsmittel...

Page 14: ...S I U OK 3 SET Three phase power factor Dreiphasenleistungsfaktor PF XXX E P Q S I U OK 3 SET P Q S I U OK 3 SET E P Q S I U OK 3 SET E P Q S I U OK 3 SET Active power L3 Wirkleistung L3 Three phase reactive power Dreiphasenblindleistung XXXX k v a r Reactive power L1 Blindleistung L1 XXXX k v a r Reactive power L2 Blindleistung L2 2 XXXX k v a r Reactive power L3 Blindleistung L3 3 XXXX k v a r P...

Page 15: ...rom L3 2 XXXX V E P Q S I U OK 3 SET 3 XXXX V E P Q S I U OK 3 SET Phase voltage L1 N Phasenspannung L1 N XXXX V P Q S I U OK 3 SET E Phase voltage L2 N Phasenspannung L2 N Phase voltage L3 N Phasenspannung L3 N 23 XXXX V E P Q S I U OK 3 SET 3 XXXX V E P Q S I U OK 3 SET Linked voltage L1 L2 Verkettete Spannung L1 L2 2 XXXX V P Q S I U OK 3 SET E Linked voltage L2 L3 Verkettete Spannung L2 L3 Lin...

Page 16: ...2 bits Nota The response time question answer time out is 200 ms maximum Kommunikation Die Energiezähler CE6DT1256 CE6DMID56 kommunizieren über das MODBUS Protokoll was einen Dialog nach einer Master Slave Logik impliziert Adressierungsart Punkt zu Punkt der Master kommuniziert mit jeweils nur einem Slave Gerät Die Kommunikation erfolgt im RTU Modus Remote Terminal Unit Kommunikationssyntax Die St...

Page 17: ...ement Imin 0 5A Itr 1A Ib 10A CE6DT1252 CE6DT1256 Iref 10A CE6DMID52 CE6DMID56 Imax 125A Current circuit power consumption Max 2 5W per phase Short time overcurrent IEC EN 62053 21 IEC EN 62053 23 30 Imax 10ms Frequency Code CE6DT1252 CE6DT1256 47 63 Hz Code CE6DMID52 CE6DMID56 49 51 Hz 59 61Hz Energies Code CE6DT1252 CE6DT1256 Active energy accuracy class 1 IEC EN 62053 21 Reactive energy accurac...

Page 18: ...with The requirements of the European directe on electromagnetic compatibility EMC n 2014 30 EU The low voltage directive n 2014 35 UE Directive 2011 65 EU modified by directive 2015 863 RoHS 2 Electromagnetic compatibility According to IEC EN 62052 11 EN 50470 1 Insulation IEC EN 62052 11 IEC EN 62053 21 Measurement category III Degree of pollution 2 Insulation voltage Ui 300V Phase Earth Impulse...

Page 19: ...1A Ib 10A CE6DT1252 CE6DT1256 Iref 10A CE6DMID52 CE6DMID56 Imax 125A Selbstverbrauch Stromkreis Max 2 5W pro Phase Kurzzeitige Überlastung IEC EN 62053 21 IEC EN 62053 23 30 Imax 10ms Frequenz Code CE6DT1252 CE6DT1256 47 63 Hz Code CE6DMID52 CE6DMID56 49 51 Hz 59 61Hz Energie Code CE6DT1252 CE6DT1256 Genauigkeitsklasse Wirkenergie 1 IEC EN 62053 21 Genauigkeitsklasse Blindenergie 2 IEC EN 62053 23...

Page 20: ...hen Den Bestimmungen der Europäischen Richtlinie über die elektromagnetische Verträglichkeit EMV Nr 2014 30 EU Der Niederspannungsrichtlinie 2014 35 EU Der Richtlinie 2011 65 EG geändert durch Richtlinie 2015 863 RoHS 2 Elektromagnetische Verträglichkeit Prüfungen gemäß IEC EN 62052 11 EN 50470 1 Isolation IEC EN 62052 11 IEC EN 62053 21 Messkategorie III Verschmutzungsgrad 2 Isolationsspannung Ui...

Page 21: ...ting Tariff 2 PF Power factor Fr Frequency Itr Transitional current Iref Reference current 10Itr Liste der Abkürzungen CodE Zugriffscode tIME Integrationszeit Leistungen Addr Adresse bAUd Kommunikationsgeschwindigkeit in kbps PAr Parität nonE Parität keine EVEn Parität Gleich odd Parität Ungerade tIM Antwortverzögerung ms PLSt Einstellung Impulsausgang ACt Wirkenergie kWh rEA Blindenergie kvarh PL...

Reviews: