background image

E150401X_ENG 

 

27/07/15 

 

 

11 

Default = 35 RPM. 

o

  FAN  SPEED:  (It  appears  only  if 

FAN  INVERTER

 is set to “YES” in the technical 

menu). It allows to select the fan speed for a given program. The speed will still be 
editable, even if in a non-definitive way, during the working process of the machine. 
Default = 2 

o

  PARTIAL  POWER:  (it  appears  only  if  the  paramete

PARTIAL  POWER

  is  set  to 

“YES” in the technical menu). 

The parameter is effective only for machines equipped with double electric heating 
remote control switch. It allows the selection of one of the two contactors, or both, to 
obtain  the  maximum  heating  power.  During  the  cycle  of  operation  it  is  however 
possible to vary the heating power used even temporary. 
 

2.  LANGUAGE 

It allows selection of one of the 10 languages available. 
 

3.  DATE/HOUR 

It allows to adjust the timing of the control board IM7. 
 

4.  CONSUMPTION 

View  energy  consumption  of  the  machine  according  to  the  values  introduced  into  the  

ENERGY MENU

" available in the technical area. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for E201003027

Page 1: ...015 SERVICE BOOK IM7 FOR TUMBLE DRYERS T MODEL SINCE SERIAL NUMBER E201003027 WITH IM7 SOFTWARE rel 2 20 OR HIGHER IMESA S p A Via degli Olmi 22 31040 Cessalto TV Italia tel 39 0421 468011 fax 39 0421...

Page 2: ...ION 11 SECTION D TECHNICAL PARAMETER MENU 12 1 ACCESS TO TECHNICAL MENU 12 2 PARAMETERS 13 1 TEMPERATURE UNIT MEASURE 13 2 TEMPERAT OFFSET 13 3 MAX TEMPERATURE DRYNG 13 4 WORKING HOURS MACHINE 14 5 TO...

Page 3: ...L POWER 20 22 COIN BOX 21 23 DEVICE TEST 22 24 LOADING TEST 23 25 ASSISTANCE PHONE 23 26 P I D 24 27 ENERGY MENU 24 28 INITIAL COOLING 24 29 STEAM CONFIGURATION 24 30 TANDEM CONFIGURATION 25 31 SEGNAL...

Page 4: ...must be trained by authorised personnel which knows the product and respecting the European Rules in matter of industrial machines installation Here described tumble dryers must be used to professiona...

Page 5: ...machine he must not be distracted by TV radio etc or being subject to any other source of distraction ATTENTION The above advices do not cover all possible risks User must proceed with maximum care r...

Page 6: ...SOR DESCRIPTION Entry into service April 2010 Installed on Driers T series Data interface NO SW upgradeable NO Programmable YES Inverter communication ANALOG and STEP Keyboard MEMBRANE DISPLAY Door lo...

Page 7: ...is possible using the arrows to scroll through the parameters and press ENTER to confirm STANDARD IM7 CONTROL CARD with IM7 COIN OP KEYBOARD o For serial numbers produced BEFORE E201310100 open the d...

Page 8: ...E150401X_ENG 27 07 15 8...

Page 9: ...me change does not entail the variation of the working temperature or time o PROGRAM TYPE Choice of the execution policy of the program If TIME is selcted the program will run for a specific time dete...

Page 10: ...is parameter Default 3 o COOLING TEMPERATURE Insert the temperature to achieve Enter the temperature to be reached during the cooling phase If the temperature is reached within the time set in the COO...

Page 11: ...menu The parameter is effective only for machines equipped with double electric heating remote control switch It allows the selection of one of the two contactors or both to obtain the maximum heatin...

Page 12: ...ENTER to confirm STANDARD IM7 CONTROL CARD with IM7 COIN OP KEYBOARD o For serial numbers produced BEFORE E201310100 open the door of the lint filter o For serial numbers produced LATER E201310101 do...

Page 13: ...59 0 68 0 77 0 86 0 95 0 104 0 113 0 122 0 131 0 140 0 149 0 158 0 167 0 176 0 185 0 194 0 2 TEMPERAT OFFSET This parameter introduces an error positive or negative to the actual reading of the tempe...

Page 14: ...RNING which appears on the display whenever you reached the maximum amount of hours described in the parameter CYCLE FOR MAINTENANCE WARNING Automatically the counter WORKING HOURS WARNING is reset De...

Page 15: ...le The inverter is installed in the rear of the machine externally with respect to the housing of the contactors 13 REVERSING DRUM The function allow to enable disable the rotation of the drum in both...

Page 16: ...FAN INVERTER The parameter allows the activation of the inverter control for adjusting the speed of the fan blower Default NO When INVERTER FAN is set to YES is provided to the operator the ability to...

Page 17: ...40 Hz 4 50 Hz The feature is not available for machine equipped by gas heating The electrical system for the drive of the fan has the following integration The inverter is installed in the rear of th...

Page 18: ...de the drum Default NO not activated If this function is activated it is necessary to introduce the following data o END CYCLE PAUSE It defines the time between the end of the cycle and the starting o...

Page 19: ...HEATING It defines the temperature margin for the ignition of the heating differential This is the difference between the set point temperature temperature set in the program and re ignition of the h...

Page 20: ...password of the technical area was lost you will need to put send back the IM7 control card unit to IMESA SPA for the full reset including further custom programs 21 PARTIAL POWER For machines equipp...

Page 21: ...YES the aspect and the behavior of the IM7 control card unit become for coin op use The COIN BOX MENU become present inside the user s menu 6 times START button The drying programs will not start if...

Page 22: ...d 23 DEVICE TEST The menu allows the testing of every device installed in the the machinery Device means any components that can be activated by the IM7 card through the relay that is attached The scr...

Page 23: ...see if the devices are efficient and if the wiring that connects them to the IM7 logic board is intact The menu appears as follows With the arrows and you can browse the various inputs Activating the...

Page 24: ...e machine s nameplate o HEATING POWER 2 Type here the heating power issued by the second set of three resistors in the machine if provided or if it is enabled PARTIAL POWER 28 INITIAL COOLING The func...

Page 25: ...set to NO and with the COIN BOX set to YES the machine no longer displays ALARM FILTER CLEANING but stops the heating and keeps working without activating the buzzer 32 FEED CONTROL This function ena...

Page 26: ...NS 2 o HYSTERESIS 3 C o COOLDOWN DELAY 0 IRON DRY o N INTERVENTIONS 0 o HYSTERESIS 10 C o COOLDOWN DELAY 0 The parameters which characterize the drying levels are o N INTERVENTIONS Each time the heati...

Page 27: ...it was used exclusively the contact N C to indicate an overload of the motors From serial number E201310101 is used the N O contact to indicate an overload The contact N C is now used to interrupt th...

Page 28: ...Type 4 times the START PAUSE button and 2 times on standard machine or type 4 times START and 2 times HIGH on coin op machines Search for parameter GESTIONE ALLARME TERMICHE and set N C on machine pro...

Reviews: