E170203X
17/02/2017
SOMMARIO
21
-
MONETARY UNIT: machines with payment system have 5 standard currency
symbols available to define a credit plus 1 extra to create your own, as per
paragraph above.
o
€
o
£
o
$
o
COINS
o
RM
o
?
-
INPUT VALUE COIN 1: when mechanical coin box, this parameter allows the
definition of one coin value showed on currency chosen by MONETARY UNIT.
Every inserted coin generates an impulse that corresponds to INPUT VALUE COIN
1.
-
INPUT VALUE COIN 2: when mechanical coin box, this parameter allows the
definition of one coin value showed on currency chosen by MONETARY UNIT.
Every inserted coin generates an impulse that corresponds to INPUT VALUE COIN
2.
-
MAX PAYMENT PULSE DURATION: it is a maximum duration time for a payment
impulse. When this impulse lasts over that limit, the computer starts an alarm for the
embedded token.
Default = 5”
4. RESIDUAL HUMIDITY
There are 3 humidity levels available and can be set on that menu.
-
IRON DRY (moisture level perfect to dry):
o
NUMBER OF INTERVENTION: it indicates how many times the heating turns
on again. This happens when the temperature goes from set point value to
hysteresis value. Every turning on corresponds to an intervention. Over a
certain NUMBER OF INTERVENTIONS the tumble dryer passes to the
following step, that is the COOL DOWN;
o
HYSTERESIS: when the set point temperature has been reached, the
heating stops and consequently the temperature naturally decreases.
Temperature decreases until it reaches the set temperature on
INTERVENTIONS. The difference between set point temperature and
interventions temperature is the hysteresis. Reaching the set intervention
temperature, heating turns on again. In the case of INTERVENTIONS
parameter is zero, the machine starts the cool down at the reaching of the
set point;
o
COOL DOWN DELAY: it is the set delay time that activates the cool down
function. It starts when the number of INTERVENTIONS has been reached.
-
DRY (standard moisture level):
o
NUMBER OF INTERVENTION
o
HYSTERESIS
o
COOL DOWN DELAY
-
EXTRA DRY (extra dry):
o
NUMBER OF INTERVENTION
o
HYSTERESIS
o
COOL DOWN DELAY
Here follow examples about automatic control functioning:
N° INTERVENTION = 0
HYSTERESIS = 5°C
COOL DOWN DELAY
= 0’