MANCANZA FIAMMA /NO FLAME
(E140901X) 25 di/of 33
This condition can be resolved by choking or by modifying the air flow that enters laterally in the heating
chamber; however, the real solution is to solve the combustion problem ensuring the correct pressure to the
burner and the correct amount of gas (eventually reconsider the gas plant or the size of the nozzles).
The solution shown in the picture (for information only) is to be considered an
expedient to certify a supply of gas not suitable for the type of dryer in use. It should
not be considered a permanent solution to apply.
4.c BURNERS INSPECTION AND CLEANING
Inside the burner the gas is mixed with the primary air.
MCA:
To check the internal cleaning of the burners is necessary to close the main external gas valve and
unscrew the yellow hose from the
machine’s gas valve. Then you can remove the burner by removing the
bracket that connects to the machine structure. The burner can be extracted. For the extraction is necessary
to have a space equivalent to the length of the machine on the left side.
SECONDARY AIR INTAKE
MCA
MCA
MCM
SUPPORT BRACKET
FOR THE BURNER