3  Safety Notes

The set corresponds to all relevant directives 
of the EU and is therefore marked with   .

3.1  Special safety notes 

for the laser unit

The laser unit features class 2M lasers . The 
laser diodes have the following power and 
wavelengths:

Power

Wavelength

green laser

  30 mW

532 nm

red laser

100 mW

650 nm

WARNING

1 .  Do not stare into the beam! 

A short-period exposure 
(0 .25 seconds max .) to the 
laser beam, however, is not 
hazardous to the eye .

2 .  Do not view the laser beam with optical 

instruments (e . g . magnifier or telescope); 
the retina may be permanently damaged .

3 .  Never point the laser beam at the eyes 

of persons or animals . Be aware of beam 
reflections on shiny surfaces; make sure 
that reflections of the laser beam do not 
hit the eye .

4 .  Do not open or modify the unit . Any 

modification may result in a more haz-
ardous laser radiation (higher laser class) .

5 .  Never leave the laser unit unattended 

during operation .

3.2  General safety notes

WARNING

The set uses dangerous mains 
voltage . Leave servicing to 
skilled personnel and do not 
insert anything into the air 
vents . Inexpert handling may 
result in electric shock .

• 

The set is suitable for indoor use only . Pro-
tect it against dripping water, splash water 
and high air humidity . The admissible ambi-
ent temperature range is 0 – 40 °C .

• 

Do not place any vessels filled with liquid, 
e . g . drinking glasses, on the unit .

• 

Immediately disconnect the mains plug 
from the socket

1 . if the set or the mains cable is visibly 

damaged,

2 . if a defect might have occurred after the 

set was dropped or suffered a similar 
 accident,

3 . if malfunctions occur .
In any case the set must be repaired by 
skilled personnel .

• 

Never pull the mains cable to disconnect 
the mains plug from the socket, always 
seize the plug .

• 

No guarantee claims for the set and no lia-
bility for any resulting personal damage or 

material damage will be accepted if the set 
is used for other purposes than originally 
intended, if it is not safely installed or not 
correctly connected or operated, or if it is 
not repaired in an expert way .

If the set is to be put out of oper-
ation definitively, take it to a local 
recycling plant for a disposal which 
is not harmful to the environment .

4  Before Operation

Install the set safely and expertly . From a legal 
point of view, the person setting up the unit 
with its additional components (e . g . mirrors, 
lenses, projection surface) to create a laser 
effect installation, is the manufacturer of this 
installation . 

Always observe the warning 

notes in chapter 3.1.

WARNING

 
Always observe the regula-
tions of the country where the 
set is operated!

When installing the set at a place where 
people may walk or sit under it, use a safety 
rope to additionally secure the set . Attach 
the safety rope to the eyebolt (14) in such 
a way that the maximum falling distance of 
the set will not exceed 20 cm .

Set up or install the FXBAR-5SET in such a way 
that sufficient air circulation will be ensured 
during operation . Always observe a minimum 
distance of 50 cm from the laser unit and the 
spotlights /derby lights to the projection sur-
face . Never cover the air vents of the housing .

4.1  Operation with a stand

1)  Place the stand on a horizontal, solid 

ground . For a safe position, spread the 
legs of the stand as far as possible and 
secure them with the locking screw .

2)  Place the controller with the lights already 

installed onto the stand and secure it with 
the locking screw .

3)  To adjust the desired height: Pull out the 

telescopic tube and put the safety pin 
through the two holes for the height de-
sired, then slide back the tube until the 
safety pin rests on the outer tube . Use 
the knob screw to additionally secure the 
telescopic tube .

IMPORTANT!

• 

Make sure that the stand is stable . Only pull 
out the telescopic tube to such an extent 
that the stand cannot fall over .

• 

Prior to operation, check all locking screws 
and fasten them, if required .

• 

Lay the connection cables in such a way 
that nobody will trip over the cables and 
knock over the stand .

4.2  Fixed installation

For fixed installation to a wall or ceiling, find a 
suitable location for the two mounting brack-
ets (8) and fasten them expertly . Use the knob 
screws provided (9) to fasten the controller to 
the brackets .

4.3  Aligning the spotlights/

derby lights and the laser unit

For aligning, unscrew the corresponding lock-
ing screws and turn/tilt the units in the de-
sired direction . Make sure that the cables are 
neither squeezed nor stretched . Then fasten 
the screws again .

4.4  Power supply

Use the mains cable provided to connect the 
mains jack “230 V~/ 50 Hz” (2) of the FX-
BAR-5SET to a mains socket (230 V/ 50 Hz) . 
The unit will be switched on . The display will 
briefly indicate the firmware version (e . g . 

 )  and the operating mode most recently 

selected .

When multiple FXBAR-5SET are used, 

use a mains cable with 3-pin IEC plug and 
3-pin IEC inline jack (e . g . AAC-170 / SW from 
 MONACOR) to connect the jack POWER LINK 
(1) of the first unit to the mains jack (2) of the 
second unit . Connect the second unit to the 
third unit etc . until all units have been con-
nected in a chain . Thus, up to 15 FXBAR-5SET 
can be interconnected .

The jack POWER LINK can also be used 

for power supply of other (light effect) units . 
However, the current load of the jacks POWER 
LINK and “230 V~/ 50 Hz” must not exceed 
6 .3 A; otherwise, overload may result in short 
circuit and fire . The fuse will not protect these 
jacks .

4.5  Wireless footswitch

When the wireless footswitch is used, unfold 
its transmitting antenna and the reception 
antenna (12) of the controller and put both 
antennas in a vertical position .

4.5.1  Conformity and approval

Herewith, MONACOR INTERNATIONAL de-
clare that the wireless footswitch and the 
reception electronics of the light effect 
set  FXBAR-5SET comply with the directive 
2014 / 53 / EU . The EU declaration of conform-
ity is available on request from  MONACOR 
INTERNATIONAL .The units are generally 
 approved for operation in EU and EFTA coun-
tries; they are 

licence-free and require no 

registration.

Summary of Contents for FXBAR-5SET

Page 1: ...CTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS BEDIENUNGSANLEITUNG INSTRUCTION MANUAL Lichteffektger te Set mit LED Scheinwerfern und Laserger t Light Effect Set with LED Spotlights LED Derby Li...

Page 2: ......

Page 3: ...ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS 3 Deutsch Seite 4 English Page 12...

Page 4: ...n sp teres Nachlesen auf 1 bersicht der Anschl sse und Bedienelemente 1 Anschluss POWER LINK zur Stromversor gung eines weiteren Ger tes 2 Netzbuchse zum Anschluss an eine Steck dose 230V 50Hz ber das...

Page 5: ...gen dass w hrend des Betriebs eine aus reichende Luftzirkulation gew hrleistet ist Das Laserger t und die Scheinwerfer m ssen einen Mindestabstand von 50cm zur Projekti onsfl che haben und die L ftun...

Page 6: ...rammen mit den Tas ten und w hlen die Kombination aller Effekte nur Blitz LEDs nur Laser nur Scheinwerfer 5 Wieder die ENTER Taste dr cken und eine Programmnummer mit den Tasten und w hlen 6 Bei den a...

Page 7: ...ndigkeit der automatisch ablaufenden Programme ohne Funktion Durch erneutes Bet tigen wird auf die n chste Programmnummer geschaltet Batterie auswechseln 1 Die Verriegelung des Batteriehalters nach re...

Page 8: ...DMX Ger te separat bedienen zu k nnen muss jedes Ger t eine eigene Startadresse erhalten Ab Werk ist f r das FXBAR 5SET die Startadresse 1 und die Steuerung mit 27 DMX Kan len eingestellt Ist die Sta...

Page 9: ...010 255 gr ner Laser blinkt lg schnell 8 000 004 keine Rotation 005 127 Rotation langsam schnell 128 133 keine Rotation 134 255 Rotation langsam schnell Blitz LEDs 9 000 004 Blitz LEDs aus 005 009 Bli...

Page 10: ...gruppe einen anderen Scheinwerfer steuern zu k nnen die Taste so oft dr cken bis die Schein werfer nummer im Display angezeigt wird Beispiel CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13 CH1...

Page 11: ...n der Geh use nur ein wei ches sauberes Tuch benutzen Auf keinen Fall eine Fl ssigkeit verwenden die k nnte in die Ger te laufen und Besch digungen verursachen 8 Technische Daten DMX Datenprotokoll DM...

Page 12: ...lation 9 Mounting screws for the brackets 8 10 Four strobe LEDs 11 Microphone for music controlled light effects 12 Antenna for the signals of the wireless footswitch 13 Laser aperture 14 Eyebolt to a...

Page 13: ...way that sufficient air circulation will be ensured during operation Always observe a minimum distance of 50cm from the laser unit and the spotlights derby lights to the projection sur face Never cov...

Page 14: ...rams use the buttons and to select combination of all effects strobe LEDs only laser only spotlights and derby lights only 5 Press the button ENTER again and use the buttons and to select a program nu...

Page 15: ...t the colours one after the other 0 9 speed of automatic programs no function Press the button again to go to the next program number Replacing the battery 1 Push the latch of the battery holder to th...

Page 16: ...t have its own start address For FXBAR 5SET start address 1 and control via 27 DMX chan nels are factory set If start address 1 is al ready used for another DMX controlled unit change the start addres...

Page 17: ...ed laser flashing slow fast 7 000 004 green laser off 005 009 green laser on 010 255 green laser flashing slow fast 8 000 004 no rotation 005 127 rotation slow fast 128 133 no rotation 134 255 rotatio...

Page 18: ...e other 4 To be able to control a different spotlight derby light with a channel group press the button repeatedly until the number of the corresponding light is indicated on the display Example CH1 C...

Page 19: ...wipe the lenses dry For cleaning the housing only use a soft clean cloth Never use any fluid it may leak into the units and damage them 8 Specifications DMX Data protocol DMX 512 Number of channels 3...

Page 20: ...MONACOR INTERNATIONAL GmbH Co KG Zum Falsch 36 28307 Bremen Germany Copyright by MONACOR INTERNATIONAL All rights reserved A 1799 00 01 09 2016...