background image

All operating elements and connections de 

-

scribed can be found on page 2.

1 Applications

This spotlight is suitable for effect illumination, e. g.
on stage or in festival rooms. It creates coloured
light via super bright 10 mm LEDs and can be oper-
ated in different modes (e. g. constant light or stro-
boscope light, automatic change of colours). The
spotlight is designed for operation via a light con-
troller with DMX512 protocol (4 or 8 DMX channels),
but it can also be operated without controller, either
as an individual unit or interconnected with several
LITEBOX-10 units in the master/slave mode.

The power can be supplied via the 230 V mains

or via the integrated lithium ion rechargeable battery
which can be recharged when connecting the unit to
the mains. Thus, the spotlight is ideally suited for
mobile applications. Via two brackets it can be set up
quickly and easily at different places of application.

2 Safety Notes

The unit corresponds to all relevant directives of
the EU and is therefore marked with 

.

It is essential to observe the following items:

G

The unit is suitable for indoor use only. Protect it
against dripping water and splash water, high air
humidity and heat (admissible ambient tempera-
ture range 0 – 40 °C).

G

Do not place any vessels filled with liquid, e. g.
drinking glasses, on the unit.

G

Do not set the unit into operation and immediately
disconnect the mains plug from the mains socket
1. if there is visible damage to the unit or to the

mains cable,

2. if a defect might have occurred after a drop or

similar accident,

3. if malfunctions occur.
The unit must in any case be repaired by skilled
personnel.

G

Never pull the mains cable to disconnect the
mains plug from the mains socket, always seize
the plug.

G

Only replace a blown fuse by one of the same
type.

G

No guarantee claims for the unit and no liability
for any resulting personal damage or material
damage will be accepted if the unit is used for
other purposes than originally intended, if it is not
safely mounted, not correctly operated, or not
repaired in an expert way.

G

Important for U. K. Customers!

The wires in this mains lead are coloured in  ac -
cord ance with the following code:
green/yellow = earth, blue = neutral, brown = live
As the colours of the wires in the mains lead of
this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
1. The wire which is coloured green and yellow

must be connected to the terminal in the plug
which is marked with the letter E or by the earth
symbol  , or coloured green or green and yel-
low.

2. The wire which is coloured blue must be con-

nected to the terminal which is marked with the
letter N or coloured black.

3. The wire which is coloured brown must be con-

nected to the terminal which is marked with the
letter L or coloured red.

Warning – This appliance must be earthed.

3 Setting-up / Mounting

Tightly screw the brackets (A) with the supplied
screws (B) at the unit 

fig. on page 2.

The unit may 
– be placed on the floor by unfolding the brackets or
– be mounted via the two brackets or the greater

one, e. g. with a stable mounting screw to a cross
bar.

To prevent heat accumulation inside the unit,
always place it so that a sufficient air circulation is
ensured during operation (minimum distance to
adjoining walls 15 cm). Never cover the air vents
at the housing.

If the unit is to be put out of operation
definitively, take it to a local recycling plant
for a disposal which is not harmful to the
environment. 

WARNING

Do not look directly into the light
source for a longer time, this may
lead to eye damage.

Please note that stroboscope effects
and fast changes in colour may
 trigger epileptic seizures with photo-
sensitive persons or persons with
epilepsy!

WARNING

The unit is supplied with hazardous
mains voltage. Leave servicing to
skilled personnel only and do not
insert anything through the air vents.
Inexpert handling or modification of
the unit may cause an electric shock
hazard. 

9

GB

Summary of Contents for LITEBOX-10

Page 1: ...ACCUMULATEUR PROIETTORE DMX A LED CON BATTERIA RICARICABILE LITEBOX 10 Bestellnummer 38 5970 BEDIENUNGSANLEITUNG INSTRUCTION MANUAL MODE D EMPLOI ISTRUZIONI PER L USO MANUAL DE INSTRUCCIONES VEILIGHE...

Page 2: ...2...

Page 3: ...D A CH GB Innan du sl r p enheten Vi nskar dig mycket gl dje med din nya img Stage Line produkt L s igenom s kerhetsf re skrifterna innan enheten tas i bruk f r att undvika skador till f ljd av felak...

Page 4: ...in eine Fachwerkstatt G Ziehen Sie den Netzstecker nie am Kabel aus der Steckdose fassen Sie immer am Stecker an G Eine durchgeschmolzene Sicherung nur durch eine gleichen Typs ersetzen G Wird das Ger...

Page 5: ...vorgang rot Akku wird geladen 5 Akkubetrieb Der Schalter POWER 6 verbleibt auf OFF Zum Einschalten des Ger ts den Schalter BAT TERY 5 auf ON stellen Die Akku Betriebszeit h ngt vom Betriebsmodus ab z...

Page 6: ...er die vier Tasten 2 bedient 1 Das Men mit der Taste MENU aufrufen 2 Den gew nschten Men punkt mit der Taste UP oder MENU oder DOWN anw hlen und mit der Taste ENTER aufrufen 3 Mit der Taste UP oder DO...

Page 7: ...en gr nen und gelben LEDs separat einstellen und damit der gew nschte Farbton einer Mischfarbe Die hier eingestellten Werte gelten nur f r das jeweilige Ger t So k nnen bei Master Slave Betrieb f r je...

Page 8: ...55 Grundhelligkeit der roten LEDs 0 100 2 0 255 Grundhelligkeit der gr nen LEDs 0 100 3 0 255 Grundhelligkeit der blauen LEDs 0 100 4 0 255 Grundhelligkeit der gelben LEDs 0 100 5 0 255 Gesamthelligke...

Page 9: ...mage will be accepted if the unit is used for other purposes than originally intended if it is not safely mounted not correctly operated or not repaired in an expert way G Important for U K Customers...

Page 10: ...the BATTERY switch 5 to ON The operating time of the battery depends on the operating mode e g up to 7 hours when all LEDs constantly light up at maximum brightness and up to 16 hours with automatic...

Page 11: ...ents The menu is operated via the four buttons 2 1 Call the menu with the button MENU 2 Select the desired menu item with the button UP or MENU or DOWN and call it with the button ENTER 3 Select the d...

Page 12: ...een and yellow LEDs can separately be adjusted and thus the desired shade of colour of a mixed colour The values adjusted here only apply to the respective unit In case of master slave mode different...

Page 13: ...nstruction manual may be reproduced in any form or by any means for any commercial use 8 CHANNEL MODE Channel DMX value Function 1 0 255 basic brightness of the red LEDs 0 100 2 0 255 basic brightness...

Page 14: ...branchez jamais l appareil en tirant sur le cordon secteur retirez toujours le cordon sec teur en tirant la fiche G Tout fusible fondu doit imp rativement tre rem plac par un fusible de m me type G No...

Page 15: ...accumulateur en charge 5 Fonctionnement accumulateur L interrupteur POWER 6 reste sur OFF Pour allumer l appareil mettez l interrupteur BAT TERY 5 sur ON La dur e de fonctionnement sur accumulateur d...

Page 16: ...2 1 Appelez le menu avec la touche MENU 2 S lectionnez le point du menu voulu avec la touche UP ou MENU ou DOWN et appelez avec la touche ENTER 3 Avec la touche UP ou DOWN s lectionnez le r glage voul...

Page 17: ...par ment la luminosit des LEDs rouges bleus vertes et jaunes et ainsi la tonalit voulue d une couleur de mixage Les valeurs r gl es ne valent que pour un seul appareil Ainsi en mode master slave on p...

Page 18: ...ht de MONACOR INTERNATIONAL GmbH Co KG Toute reproduction m me partielle des fins commerciales est interdite MODE 8 CANAUX Canal Valeur DMX Fonction 1 0 255 luminosit de base des LEDs rouges 0 100 2 0...

Page 19: ...o d uso improprio di montaggio non sicuro d impiego scorretto o di riparazione non a regola d arte dell apparecchio non si assume nessuna responsabilit per eventuali danni con sequenziali a persone o...

Page 20: ...su OFF Per accendere l apparecchio mettere l interruttore BATTERY 5 su ON La durata della batteria dipende dal modo di funzionamento p es fino a 7 ore se tutti i LED sono accesi costantemente con la m...

Page 21: ...omandato tramite i quattro tasti 2 1 Chiamare il men con il tasto MENU 2 Scegliere la voce desiderata del men con il tasto UP o MENU o DOWN e chiamarla con il tasto ENTER 3 Con il tasto UP o DOWN sceg...

Page 22: ...la lumi nosit dei LED rossi blu verdi e gialli e quindi la tonalit cromatica di un colore miscelato I valori indicati qui sono validi solo per il relativo apparecchio Con il funzionamento master slav...

Page 23: ...ualsiasi forma delle presenti istruzioni per l uso La riproduzione anche parziale per propri scopi commerciali vietata MODO A 8 CANALI Canale Valore DMX Funzione 1 0 255 Luminosit base dei LED rossi 0...

Page 24: ...empre un fusible fundido s lo por otro del mismo tipo G No podr reclamarse garant a o responsabilidad alguna por cualquier da o personal o material resultante si el aparato se utiliza para otros fines...

Page 25: ...uptor BAT TERY 5 en posici n ON El tiempo de funciona miento de la bater a depende del modo de funcio namiento p ej hasta 7 horas cuando todos los LEDs se iluminan constantemente y con el brillo m xim...

Page 26: ...cuatro botones 2 1 Abra el men con el bot n MENU 2 Seleccione el objeto del men con el bot n UP o MENU o DOWN y act velo con el bot n ENTER 3 Seleccione el ajuste que desee con el bot n UP o DOWN y co...

Page 27: ...e los LEDs rojos azules verdes y amarillos por separado y por lo tanto el matiz del color de un color mezclado Los valores que se ajus tan aqu s lo se aplican en el aparato concreto En el modo Master...

Page 28: ...o por el copyright de MONACOR INTERNATIONAL GmbH Co KG Toda reproducci n mismo parcial para fines comerciales est prohibida MODO 8 CANALES Canal Valor DMX Funci n 1 0 255 Brillo b sico de los LEDs roj...

Page 29: ...29...

Page 30: ...ds zo dat bij het gebruik voldoende ventilatie is gegarandeerd De afstand tot de belendende muren moet minstens 15 cm bedragen De ventilatieopeningen in de behuizing mogen in geen geval zijn afgedekt...

Page 31: ...czas pracy nale y zawsze zapewni swobodn cyrkulacj powietrza wok urz dzenia W przeciw nym razie mo e nast powa przegrzanie urz dze nia Minimalny dystans od najbli szej ciany musi wynosi minimum 15 cm...

Page 32: ...autoriseret personel omfattes eventuelle ska der ikke af garantien Opsaetning montering Plac r altid enheden s der er rigeligt med ventila tion omkring denne Minimumsafstand til v g er 15 cm Kabinette...

Page 33: ...en skada p person eller materiel Placering montering Placera enheten s att luften kan cirkulera fritt runt den och t pp inte till kylh len i chassiet Minsta avst nd till v ggar r 15 cm Reng ring Reng...

Page 34: ...masti k ytetty tai asennettu tai jos laitetta on huollettu muussa kuin valtuutetussa huollossa Asennus Asenna laite aina siten ett riitt v ilmankierto on varmistettu k yt n aikana J t v hint n 15 cm t...

Page 35: ...MONACOR INTERNATIONAL GmbH Co KG Zum Falsch 36 28307 Bremen Germany Copyright by MONACOR INTERNATIONAL All rights reserved A 1306 99 01 02 2012...

Reviews: