background image

7

8

 

Section 4. Reference 

Control Menu

DMX protocol

Specification

s

Control Menu 

Section 3. Troubleshooting 

Troubleshooting 

Problem 

Probable cause(s) 

Remedy 

No response from 

fixture when power 

is applies 

No power to fixture 

Check power cables 

Fixture resets but 

does not respond 

correctly to 

controller(DMX 

mode operation) 

Controller not 

connected 

Connect controller 

Incorrect 

addressing of the 

fixtures 

Check address setting on fixture and controller 

Bad data link 

connection 

Inspect cables and correct poor connections 

and/or broken cables. 

Conflict between 

tracking and vector 

control 

Eliminate scene cross-fade on controller 

Data link not 

terminated 

Insert termination plug in output of last fixture 

Defective fixture or 

2 devices 

transmitting on link 

Bypass fixtures one at a time until normal 

operation is regained:unplug both connectors 

and connect them directly together 

Colors cannot be 

mixed 

Random color 

mixing is on 

Turn off random color mixing 

Fixture does not 

reset correctly 

Electronic or 

mechanical failure 

Contact service technician 

DMX

3

DMX

1

Channel

Channel

White,000-255 dimmer

Summary of Contents for PARC-100E/WWS

Page 1: ...ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS INSTRUCTION MANUAL COB LED Spotlight PARC 100E WWS Order No 38 8100...

Page 2: ...fy the shipper immediately and keep the packing material for inspection Again please save the carton and all packing materials If the fixture must be returned to manufacturer it is important that the...

Page 3: ...t least 1m away from adjacent surfaces Be sure that no ventilation slots are blocked Fixture may carry high heat do not aim at objective exceeding 2 minutes Safe wire should be used to install machine...

Page 4: ...and wire it between pins 2 3 of the last fixture They are also readily available from specialty retailers Complimentary signal cable can transmits signals to 20 unit fixtures at most Signal amplifier...

Page 5: ...Bad data link connection Inspect cables and correct poor connections and or broken cables Conflict between tracking and vector control Eliminate scene cross fade on controller Data link not terminated...

Page 6: ...ter system is independent with detective fan working system DMX Protocol 3CH Channel Function Effect 1 Dimmer 0 255 White linear dimmer from dark to light 2 Strobe 0 1 No applicable 2 255 strobe speed...

Page 7: ...all fixtures same addresses value or subject to DMX console performance Attention all fixtures use the same DMX channel 3 or 1CH Specifications Power supply Operating voltage Power consumption operati...

Reviews: