background image

4

Vento V.1

S

in

S

out

Optional

Pleno / Pleno Refill  

Swm

Pleno P BA4 R  

Pleno P AB 5 

Pleno P AB5 R + Pleno Refill  

Pleno P BA4 R + Pleno Refill 

WM

V 10/14

Sin1

Sout

Vento V.1 E(C) 

TecBox 

V1

V3

PT

SYS

PT

ECO

PT

W

FL

S

wm

S

out

S

wm

S

in

V.4_, V.6_, V.8_  

 

 

V.10_, V.14_

 

V_4.1 V_6.1 V_8.1 V_10.1 V_14.1

dpu min bar 

1

1,5

2

3,5

5,5

dpu max bar  2,5

3,5

4,5

6,5

10

Sin1 Sout Swm

Ts min

°C 

0

0

0

Ts max

°C 

90

90

65

Summary of Contents for PNEUMATEX Vento Connect V 4

Page 1: ...ally Dirt trap SF Inspect and clean if necessary after a drop in the water make up capacity or before functional testing of the backflow preventer BA We recommend including the Pleno P P R P CR BA4R in the maintenance cycle of the connected pressure maintaining or degassing station Follow the maintenance instructions for Refill softening modules The Pleno P P R P CR BA4R can work as an accessory i...

Page 2: ...1 2 2 1 ...

Page 3: ...3 600 5 C 40 C 1x230V 400 Swm max qwm 1300 l h Refill 6000 12000 Refill Demin 2000 4000 max qwm 1300 l h Refill 16000 36000 48000 Refill Demin 13500 18000 ...

Page 4: ...R Pleno Refill Pleno P BA4 R Pleno Refill WM V 10 14 Sin1 Sout Vento V 1 E C TecBox V1 V3 PT SYS PT ECO PT W FL Swm Sout Swm Sin V 4_ V 6_ V 8_ V 10_ V 14_ V_4 1 V_6 1 V_8 1 V_10 1 V_14 1 dpu min bar 1 1 5 2 3 5 5 5 dpu max bar 2 5 3 5 4 5 6 5 10 Sin1 Sout Swm Ts min C 0 0 0 Ts max C 90 90 65 ...

Page 5: ...0 m DNe 25 25 25 25 25 L max 30 m DNe 32 32 32 32 32 tR Q psvs Hst P ZUT tmax DSV DGH 500 mm Statico SD SU min SD 80 DLV Zeparo G Force DNe Sin1 Sout Swm pw 2 10 bar tw 5 65 C Vento Connect TecBox Sin1 Sout Swm DNe tR Q psvs Hst P ZUT tmax DSV DGH 500 mm Statico SD SU min SD 80 DLV Zeparo G Force Sin1 DNe Sout Vento Connect TecBox Swm pw 2 8 bar tw 5 30 C ...

Page 6: ...6 230V 50 Hz 10A 3 x 1 0 mm 5 1 2 L PE N L PE N 3 4 6 1 BrainCube Connect 1 5 V 1 10A www imi hydronic com ...

Page 7: ...p a r a m e t r e s B u i l d i n g c o n t r o l r e p o r t s a l l o c a t i o n a c c t o m e n u p a r a m e t e r C NO C NO C NO A A c h t u n g F r e m d s p a n n u n g A t t e n t i o n t e n s i o n e x t e r n e A t t e n t i o n e x t e r n a l v o l t a g e B N B U G N Y E B N B U G N Y E B N B U G N Y E B N B U G N Y E B N B U G N Y E M 1 LINE P C1 V1 V3 V4 WM V2 P C2 OD1OD2 OD3OD4 L...

Page 8: ...N GND IN GND IN A B S A B S ID6 ID5 IDA3 q NPN SHIELD SHIELD RS 485 ID6 ID5 IDA3 USB RS458 LAN Ethernet A B S A B S IN OUT Jumper RS485 off Offen stationne open on Gesteckt branche connect GND IN GND IN GND IN A B S A B S M 1 LINE P C1 V1 V3 V4 WM V2 P C2 OD1OD2 OD3OD4 L N PE L N PE L N PE 13 14 13 14 13 14 Klemmen Ausführung C Version des bornes C Terminal execution C 230 V 50 Hz F201 Sicherung f...

Reviews: