-  * Temperature adjustment with a domestic hot 

water flow of 9.3l/min. with inlet temperature 

of 15°C.

- The data relating to domestic hot water 

performance refer to a dynamic inlet pressure 

of 2 bar and an inlet temperature of 15°C; the 

values are measured immediately at the boiler 

outlet, considering that to obtain the data 

declared, mixing with cold water is required.

3.17 COMBUSTION PARAMETERS.

3.18 TECHNICAL DATA.

Nominal heat input

kW (kcal/h)

30,9 (26571)

Minimum heat input

kW (kcal/h)

12 (10356)

Nominal heat output (useful)

kW (kcal/h)

27,9 (23994)

Minimum heat output (useful)

kW (kcal/h)

10,5 (9030)

Efficiency at nominal heat output

%

90,3

Efficiency at 30% nominal heat output load

%

89,3

Heat loss at case with burner On/Off

%

3,60 / 1,07

Heat loss at flue with burner On/Off 

%

6,10 / 0,24

Central heating circuit max. operating pressure

bar

3

Central heating circuit max. operating temperature

°C

90

Adjustable central heating temperature

°C

38 - 85

System expansion vessel total volume

l

4,5

Expansion vessel factory-set pressure

bar

1

Water content in generator

l

2,9

Head available with 1000 l/h flow rate

kPa (m H

2

O)

28,9 (2,95)

Hot water production useful heat output

kW (kcal/h)

27,9 (23994)

Domestic hot water adjustable temperature

°C

38 - 77

Domestic hot water circuit flow limiter

l/min

11

Domestic circuit min. pressure (dynamic)

bar

0,3

Domestic hot water circuit max. working pressure

bar

10

Minimum D.H.W. flow rate

l/min

1,5

Specific flow rate (∆T 30°C)

l/min

12,8

Flow rate capacity in continuous duty (∆T 30°C)

l/min

13,2

Weight of full boiler

kg

33,9

Weight of empty boiler

kg

31,0

Electrical connection

V/Hz

230/50

Nominal absorption

A

0,5

Installed electric output

W

120

Pump consumption

W

98

Equipment electrical system protection

-

IPX4D

Boiler flue circuit resistance

Pa

1,3

NO

X

 class

-

3

Weighted NO

X

mg/kWh

140

Weighted CO

mg/kWh

32

Type of appliance

B11BS

Category

II2H3+

G20

G30

G31

Gas nozzle diameter

mm

1,30

0,78

0,78

Supply pressure

mbar (mm H

2

O)

20 (204)

29 (296)

37 (377)

Flue flow rate at nominal heat output

kg/h

73

69

72

Flue flow rate at min heat output

kg/h

63

63

63

CO

2

 at Q. Nom./Min.

%

6,00 / 2,60

7,40 / 3,00

7,00 / 3,00

CO with 0% O

2

 at Nom./Min. Q. Nom./Min.

ppm

70 / 32

133 / 53

77 / 41

NO

X

 at 0% of O

2

 at Q. Nom./Min.

mg/kWh

231 / 134

356 / 139

420 / 150

Flue temperature at nominal output

°C

100

107

103

Flue temperature at minimum output

°C

79

79

79

- The maximum sound level emitted during 

boiler operation is < 55dBA. The sound level 

value is referred to semianechoic chamber tests 

with the boiler operating at max. heat output, 

with extension of the flue gas exhaust system 

according to product standards.

Summary of Contents for 3.018921

Page 1: ...NIKE MINI 28 KW SPECIAL Instruction and warning booklet 1 040845ENG...

Page 2: ...as boilers As for the other issues related to boiler installation e g safety in the work site environment protection injury prevention it is necessary to comply with the provisions specified in the re...

Page 3: ...l heating system pressure 12 2 9 System draining 12 2 10 Anti freeze protection 12 2 11 Case cleaning 12 2 12 Decommissioning 12 3 Boiler start up initial check 13 3 1 Hydraulic diagram 13 3 2 Wiring...

Page 4: ...ies personal responsibility and invalidates the warranty Installation regulations theseboilerscannotbeinstalledinbedrooms studio flats and bathrooms They also cannot be installed in rooms with wood or...

Page 5: ...type used in the boiler which must comply with the regulations in force as insufficient levels can reduce generator output and cause malfunctions Ensure correct gas cock connection by following the m...

Page 6: ...ergas chrono thermostats are connected with 2 wires only Carefully read the user and assembly instructions contained in the accessory kit On Offdigitalchrono thermostat Thechrono thermostat allows set...

Page 7: ...dangerous situations for the user The flue ducts must be connected to the chimney or flue in the same room in which the appliance is installed or at most in the adjoining room and must comply with the...

Page 8: ...intervenes in the eventofgassupplyfailureandchecktherelative intervention time check activation of the main switch located upstream of the boiler The boiler must not be started up even if only one of...

Page 9: ...safety thermostat 6 Fumes hood 7 Delivery probe 8 Safety thermostat 9 System expansion vessel 10 Combustion chamber 11 Boiler circulator pump 12 3 bar safety valve 13 By pass 14 Three way valve motor...

Page 10: ...onnected parts with easily flammable substances Never leave containers or flammable substances in the same environment as the appliance It is prohibited and dangerous to obstruct the air intake even p...

Page 11: ...tacts resistance block LEDs 2 and 7 flash at the same time 04 Parasite flame block LEDs 1 and 7 flash at the same time 20 Loss of remote control communication LEDs 2 and 3 flash alternately 31 Insuffi...

Page 12: ...ure via the valve located at the bottom of the boiler Fig 2 2 N B close the valve after the operation If pressure values reach around 3 bar the safety valve may be activated In this case contact a pro...

Page 13: ...he exit of the appliance combustion products check that there is no backflow of combustion products into the room even during functioning of fans ensure activation of all adjustment devices seal the g...

Page 14: ...ent interventions of the over heating safety thermostat It can depend on reduced water pressure in the boiler little circulation in the heating system the blocked pump or an anomaly of the boiler P C...

Page 15: ...perations must be carried out by a qualified technician e g After Sales Technical Assistance Service Burner adjustment must be carried out using a U or digital pressure gauge connected to the gas valv...

Page 16: ...tables Heating output The boiler is produced and calibrated in the central heating phase at nominal output Permanent reduction of the timer The boiler has an electronic timing device that prevents the...

Page 17: ...with boiler in standby the function activates every 18 hours after the last boiler check power supply In case of functioning in domestic hot water mode the self check starts within 10 minutes after t...

Page 18: ...anel 4 towards you taking care to remove the 2 fixing screws 5 3 16 HEAT OUTPUT N B gasflowratesrefertoheatingpowerbelowa temperature of 15 C and a pressure of 1013 mbar Burner pressure values refer t...

Page 19: ...3994 Domestic hot water adjustable temperature C 38 77 Domestic hot water circuit flow limiter l min 11 Domestic circuit min pressure dynamic bar 0 3 Domestic hot water circuit max working pressure ba...

Page 20: ...Model Cod Md Model code Sr N Serial Number CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum DHW heat input Qn min CH minimum heat input Qnw max DHW maximum heat in...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...Europe S r o 059051 Poprad Matejovce SK Tel 421 524314311 Fax 421 524314316 IMMERGAS SPA ITALY CERTIFIED COMPANY UNI EN ISO 9001 2015 Design manufacture and post sale assistance of gas boilers gas wat...

Reviews: