27
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
Information menu (“M1”).
This menu contains the various information relative to boiler functioning:
1st
Level Button 2nd Level
Button
3rd Level
Button
4th Level
Button
Description
M3
D
C
P31
D
C
AUTO
(Default)
D
x
select
C
The display lights up when the burner is ignited
and when the controls are accessed, it remains on
for 5 seconds after the last operation performed
ON
The display is always lit up
OFF
The display only lights up when the controls are
accessed and remains on for 5 seconds after the
last operation performed
P32
D
C
P32/B
D
C
ITALIANO
D
x
select
C
All descriptions are given in Italian
A1
(Default)
All descriptions are given in alphanumerical
format
P33
D
C
OFF
(Default)
D
x
select
C
In winter mode, by activating this function it is
possible to activate the room central heating func-
tion even if the eventual Remote Control or TA
are out of service.
ON
RESET
D
x
select
C
By pressing “D”, the customisations are reset, re-
storing the default values of P31 in “ILL. AUTO”
and P32/B in “ITALIANO” set by default.
Customisations Menu (“M3”).
This menu
contains all functioning options that can be
customised. (The first item of the various options
that appears inside the parameter is that selected
by default).
Attention:
if the international language is to be
restored
(A1)
, proceed as follows:
2.7 PARAMETERS AND INFORMATION
MENU.
By pressing the button "D" it is possible to access
a menu divided into three main parts:
- “M1” information;
- “M3” customisations;
- “M5” configurations: menu reserved to the
technician and for which a password is required
(See “Maintenance” chapter).
By turning the central heating temperature se-
lector switch (3) scroll through the menu items.
By pressing button “D” access the various levels
of the menu and the choice of parameters is
confirmed. Press button “C” to go back one level.
- press button "D" to enter the configuration
menu.
- turn selector switch "3" to
“PERSONAL”
.
- press button "D" to confirm.
- turn selector switch "3" to
“DATI”
.
- press button "D" to confirm.
- turn selector switch "3" to
“LINGUA”
.
- press button "D" to confirm.
- turn selector switch "3" to
“A1”
.
- press button "D" to confirm.
At this point, the items indicated in the menu
tables appear on the display.
1st
Level Button
2nd Level
Button
3rd Level
Button
Description
M1
D
C
P11
D
C
View the management software version of the P.C.B. installed in the boiler
P12
View the total functioning hours of the boiler
P13
View the number of burner ignitions
P14
(with optional
external probe
present)
- - -
(without external
probe (optional)
D
C
P14/A
View the current external temperature (if optional external probe present)
P14/B
View the minimum external temperature recorded (if optional external
probe present)
P14/C
View the maximum external temperature recorded (if optional external
probe present)
RESET
D
x
select
C
By pressing button “D” the MIN and MAX temperatures are brought to the
default value of 25 °C
P15
D
C
View the value of the domestic hot water flow rate from the flow meter
P17
View the fan instantaneous rotation percentage speed (in RPM)
P18
View the circulator pump instantaneous speed (in %)
P19
View the last 5 events that caused boiler shutdown. Indicator (6) shows the
sequential number from 1 to 5 and on indicator (7) the relative error code.
By pressing button "D" repeatedly it is possible to view the functioning
time and the number of ignitions at which the anomaly occurred