background image

5

INS

TALLER

US

ER

MAINTEN

AN

CE TECHNI

CI

AN

1

  STORAGE TANK UNIT  

INSTALLATION

1.1 INSTALLATION 

RECOMMENDATIONS.

The place of installation of the appliance and 

relative Immergas accessories must have suitable 

features (technical and structural) such to allow 

(always in safety, efficiency and comfortable 

conditions):

-  installation (according to the provisions of the 

technical legislation and technical regulations);

-  maintenance operations (including scheduled, 

periodic, routine and special maintenance);

- removal (to outdoors in the place for loading 

and transporting the appliances and compo-

nents) as well as their eventual replacement 

with appliances and/or equivalent components.

Only professionally enabled companies are au-

thorised to install Immergas appliances. 

Installation must be carried out according to 

regulation standards, current legislation and 

in compliance with local technical regulations 

and the required technical procedures. Before 

installing the storage tank unit, ensure that it is 

delivered in perfect condition; if in doubt, contact 

the supplier immediately. Packing materials (sta-

ples, nails, plastic bags, polystyrene foam, etc.) 

constitute a hazard and must be kept out of the 

reach of children. 
If the storage tank unit is installed inside or 

between cabinets, ensure there is sufficient space 

for normal servicing. It is advisable to leave an 

adequate gap between the storage tank casing 

and the sides of the cabinet.

A space of at least 650 mm is to be left in the 

upper part and 450 mm in the inspection and 

sacrificial anode connection areas.
In the event of a malfunction, fault or incorrect 

-operation, disable the storage tank unit and 

contact an authorised company (e.g. the Au-

thorised Technical Assistance centre, which has 

specifically trained staff and original spare parts). 

Do not attempt to modify or repair the appliance 

alone. Immergas is to comply with the conditions 

specified in the conventional warranty contract 

during the period of validity of the said warranty.

Failure to comply with the above implies personal 

responsibility and invalidates the warranty.
• Installation regulations: previously check the 

features of the place of installation regarding 

clearance and total weight of the accumulation, 

if necessary placing a support surface under the 

storage tank in order to optimise distribution 

of the weight. These storage tanks have been 

designed only for floor installation; they must 

be used for the storage of domestic hot water 

for domestic and similar uses. They have not 

been designed for wall installation. Make sure 

that the volume and pre-charged pressure of 

the expansion tank of the secondary circuit are 

suitable for the system;

N.B.:

 It is mandatory to have a properly sized 

safety valve and expansion vessel to place on 

both hydraulic circuits.

Important:

 this storage unit is used to produce 

and store hot water; it must therefore be con-

nected to a heating plant, to a domestic hot 

water distribution network and a water system, 

which are compatible with its performance and 

power. The materials used for the installation and 

connection must be completely compatible with 

the minimum features requested for solar use.

It must be installed in an environment where the 

temperature cannot fall below°C. It must not be 

exposed to atmospheric agents.

Summary of Contents for 3.027746

Page 1: ...Instruction and recommendation booklet IE INOXSTOR 200 300 500 V2 Storage tank 1 041259ENG ...

Page 2: ......

Page 3: ...n it is necessary to comply with the provisions specified in the regulations in force and principles of good practice In compliance with legislation in force the systems must be designed by qualified professionals within the dimensional limits established by the Law Instal lation and maintenance must be performed in compliance with the regulations in force according to the manufacturer s instructi...

Page 4: ...unit 7 1 6 Main components 7 1 7 Kit available on request 8 2 User and maintenance instructions 9 2 1 Cleaning and maintenance 9 2 2 Functioning 9 2 3 Emptying the storage tank unit 9 2 4 Case cleaning 9 2 5 Decommissioning 9 3 Control and maintenance 10 3 1 Functional layout 10 3 2 Yearly control and maintenance of the storage unit 11 3 3 Storage unit technical data 11 3 4 Product data sheet in c...

Page 5: ...ection areas In the event of a malfunction fault or incorrect operation disable the storage tank unit and contact an authorised company e g the Au thorised Technical Assistance centre which has specifically trained staff and original spare parts Do not attempt to modify or repair the appliance alone Immergas is to comply with the conditions specified in the conventional warranty contract during th...

Page 6: ...utlet B2 Domestic hot water probe B12 Storage tank solar probe E15 Storage tank integration resistance optional T DHW thermometer X Distance above ground to fix circulation unit Unused DHW side hydraulic connections are to be closed with hydraulic seal caps All connection fittings must be adequately insu lated to minimise heat dispersion Insulated caps to be applied on unused fittings during insta...

Page 7: ...g and bottom which guarantees a long life The assembly concepts and welding T I G are implemented to the minimum detail to ensure maximum reliability Efficiency the coiled heat exchange surface is sized to supply large quantities of hot water The storage tank has two seats to include the sacrificial anode which is supplied as standard to protect the inner part of the storage tank against corrosion...

Page 8: ...uest The storage tank unit is set up for application of an integration resistance to provide the anti freeze function which can be calibrated by a specific thermostat Electronic anode kit The storage tank is set up for the installation of the electronic anode Direct current is made to circulate between the device and the tank to be protected via a special titanium anode screwed on and located insi...

Page 9: ...ween 60 and 65 C because this temperature guarantees the best performance of the storage tank unit and at the same time ensures maximum hygiene maximum affordability delay in lime scale formation The DHW in the storage tank is heated with the passage of CH solar water which circulates inside the coils inside the storage tank unit itself In all cases the maximum temperature inside the storage tank ...

Page 10: ...ectronic control unit 3 Circulation solar unit 4 Solar system expansion vessel 5 6 bar safety valve 6 System probe and venting unit 7 Mixer valve 8 Storage unit 9 Storage unit thermometer 10 Inspection flange 11 Domestic hot water connection NTC 10 k hom at 25 C supplied as standard 12 Solar panels probe connection AC Domestic hot water outlet AF Domestic cold water inlet MU Storage unit delivery ...

Page 11: ... TECHNICAL DATA INOXSTOR 200 INOXSTOR 300 INOXSTOR 500 Hydraulic performances Storage tank unit capacity l 202 6 279 480 3 Domestic hot water side maximum pressure bar 8 8 8 DHW side maximum temperature C 99 99 99 Maximum coil pressure bar 6 6 6 Central heating side maximum temperature C 90 90 90 Empty storage tank unit weight kg 60 7 75 0 101 0 Full storage tank unit weight kg 274 9 366 1 598 9 H...